Installation Instructions:

 

INSTALLATION: VALVE KIT WITH PRE-INSTALLED LOG SET:

 

1.  Make sure gas is completely turned OFF to the gas log set. Make sure you have a certified and approved shut-off 

within 6-feet of the fireplace, or per the local code requirements.

2.  Remove all logs and basket grate and set aside.

3.  Disconnect the 3/8” flared fitting on the existing manual valve from the inlet gas supply.

4.  Remove existing manual valve and fittings on the burner pan.

5.  Locate a position for the pilot assembly on the back of the burner pan about 4-inches from the right or left side of the 

burner pan (See Fig 9).

6.  Mount pilot assembly to burner pan as shown in (Fig. 9). 

Not

e: This pilot bracket clips on the top edge of burner pan 

and holds the pilot at a 45° position onto the pan, an attachment screw is recommended. Bend pilot tubing from pilot 

assembly until the bottom of the pilot bracket is resting against the pan. This will hold the pilot at the 45º position. (Use 

caution when bending pilot tubing not to kink the tubing and when locating the igniter and flame sensor wires not to 

locate the wires and the tubing in or over the burner pan.)   

7.  Locate the valve kit in the right or left front corner of the firebox as far forward as possible (See Fig. 10).

8.  Bend inlet gas supply line and connect the 3/8” flare fitting to 3/8” 

inlet

 fitting on the gas valve. (Use caution not to 

kink the aluminum inlet line when bending to fit to the valve). 

Note:

 Use the UR3-68 adapter (if needed) for inlet or 

outlet gas supply.

9.  Bend 12” stainless flex line and connect it to the valve 

outlet,

 then connect other end to 3/8” flare fitting to existing 

burner pan. 

Caution:

 Ensure no gas line, inlet or outlet, are placed over top of the burner pan.

10. Turn ON gas supply and check all connections for leaks using soapy water solution.

11.  Follow valve lighting instructions. After the pilot is operating, check pilot fittings for leaks.

12. Reinstall basket grate and logs.

13. Install Damper clamp (supplied with valve kit) which allows damper to remain slightly open to allow the pilot gases to 

vent). 

NOTE: For any PROPANE installations see conversion kit instructions.

INSTALLATION PRECAUTIONS

These instructions must be used as a supplement to the instructions supplied with the gas log set. Follow the gas log 

instructions supplied by the manufacturer on the placement of the burner pan, log basket grate, burner media (sand or 

vermiculite), ember material and the log placement. Please follow these instructions on the connection of the inlet line to 

the gas valve and to the burner pan assembly. If this fireplace installation has glass doors, only operate the fireplace with 

glass doors in the fully open position.   

This electronic safety pilot system contains a valve, pilot assembly, module and connector that are certified by CSA under 

file report number 224930.

NOTE: 

VALVE BOX MUST BE LOCATED A MINIMUM OF 2-INCHES FROM SIDES OF BASKET GRATE AND 

NEVER PLACED DIRECTLY IN FRONT OR BEHIND THE BASKET GRATE.

Fig. 9

 Pilot Bracket Installation

Burner Pan

4.00”

Pilot Bracket

  Screw 

not supplied

Hook pilot bracket over back 

edge of burner pan

Secure bracket to 

burner pan (screw 

not supplied)

Top edge of 

burner pan

Pilot assembly 

bracket

Pilot 

assembly

Pilot Mounting Detail

Содержание AFVK-SP

Страница 1: ...tice Please leave these instructions for the consumer Retain for future reference Models AFVK SP AFVK SP HL AFVK SP MHL Electronic Safety Pilot System for Vented Gas Logs IF YOU CANNOT READ OR UNDERST...

Страница 2: ...Set Page 5 Reference Section Wiring Diagram Page 6 Battery Pack Preparation Page 7 Gas Conversion Page 8 Operation of System Page 9 10 Troubleshooting Page11 Replacement Parts Page 12 Warranty Page12...

Страница 3: ...Solenoid ON Remote Switch Continious Pilot On Off Switch AFVK SP HL Side View inside box Fig 4 AFVK SP HL Hi Lo Solenoid SP1001HL trans mitter damper clamp flex line adapter fitting includes battery p...

Страница 4: ...et gas supply 9 Bend 12 stainless flex line and connect it to the valve outlet then connect other end to 3 8 flare fitting to existing burner pan Caution Ensure no gas line inlet or outlet are placed...

Страница 5: ...ilot tubing from pilot assembly until the bottom of the pilot bracket is resting against the pan This will hold the pilot at the 45 position Use caution when bending pilot tubing not to kink the tubin...

Страница 6: ...itor Wires Fig 11 Module Identification IN PILOT OUT PILOT ADJ MAIN MAIN 2 Pin Connector Green White Wires PILOT 2 Pin Connector Orange White Wires Pilot Ass y Fig 12 Gas Valve Identification OUT PILO...

Страница 7: ...r on the battery pack comes pre installed to the 4 pin female connector located on the battery pack and module Note Figs 14 16 for reference 2 The AFVK SP HL AFVK SP MHL also has 2 18 wires Red Black...

Страница 8: ...ROPANE it will be necessary to use the LPK 18 or LPK 24 1 The AFVK SP AFVK SP HL or AFVK SP MHL electronic control valves are convertible from Natural gas to Propane gas by simply turning the stem kno...

Страница 9: ...OFF OFF REMOTE ON OFF CONTINUOUS PILOT Fig 20 Valve box switches Fig 21 Remote control Continuous button 2 REMOTE CONTROL FEATURE The AFVK SP AFVK SP HL or AFVK SP MHL comes with a remote control tra...

Страница 10: ...ilot is lit 2 seconds the main burner will light 3 Adjust the main flame from HI to LO with the manual HI LO knob on front of valve kit Note Move the OFF REMOTE slide switch on the face plate of valve...

Страница 11: ...e continuous pilot switch to the OFF position MAIN BURNER DOES NOT COME ON WHEN THE MANUAL ROCKER SWITCH OR REMOTE CONTROL IS TURNED ON 1 Confirm that the pilot sparks and lights 2 Check the 2 pin pla...

Страница 12: ...tinuous Pilot Off On AUX OUT PILOT ADJ IN MAIN PILOT 10 11 LIMITED WARRANTY American Flame warrants the AFVK SP AFVK SP HL or AFVK SP MHL Valve Kit for 12 months from the date of purchase or installat...

Отзывы: