american flame AF-LMF Скачать руководство пользователя страница 8

American  Flame: AF-LMF Series Valve Kits

 

Rev. 4-26-21  Page 8

MAINTENANCE OF YOUR AF-LMF SERIES VALVE KITS

Your system should be checked once a year (at start of heating season) for proper operation by a qualified serviceman.  

Items to check: Valve operation, pilot operation, switch operation, damper operation, visual check of the burner and check 

gas connections for any leaks.

TROUBLESHOOTING

1.   When lighting pilot, ensure you wait at least 30 seconds to one minute for the thermocouple to heat up before 

releasing the black control knob.  See lighting instructions.

2.   Check the connection from the pilot assembly to the gas valve.  Follow the copper wire to the gas valve and ensure the 

fitting is snug and not too tight.  The connection should only be installed finger tight plus a quarter turn with a wrench. 

See Fig. 15 for reference.

3.   Over time the thermocouple can get dirty with a white or soot film.  This can cause the pilot not to stay lit or light at all.  

Clean off the thermocouple and wipe off dust and try again.

4.   If pilot will not light at all, then replace thermocouple or the entire pilot assembly.

5.   If pilot flame it too large, noisy, or too small, it can be adjusted with the pilot adjustment screw by removing the two 

screws from the front cover of the valve box.  See Fig 16.

PILOT WILL NOT STAY LIT

REMOTE WILL NOT LIGHT BURNER

1.   Ensure the pilot is lit and the control knob is in the ON position. See Fig.14.

2.   Ensure the transmitter is “LEARNED” to the receiver.  See page 6 as reference.

3.   Check the black slide switch on the receiver.  The switch should be in the REMOTE position.  See Fig. 13.

4.   Check the (4) batteries in the receiver.  The total voltage of all (4) batteries should not be less than 5.3 volts.

5.   Check the transmitter battery/batteries; there should be a red LED light glow when pressing any button on the remote 

control.  

Note

: The 12-volt battery should be no less than 9 volts and ensure the batteries are not installed backwards.

FOR TECHNICAL                                    U.S. INQUIRIES  

CANADIAN INQUIRIES

SERVICE, CALL:

 

(855) 498-8324 or (260) 459-1703 

       (877) 472-3923 

American Flame

9230 Conservation Way

Fort Wayne, IN 46809

Sales Support: (888) 699-6167

Website: www.skytechpg.com

OFF

PILOT

ON

Pilot Adjustment 

Screw (brass)

Fig. 16

 Pilot adjustment.  Clockwise decreases flame; 

Counter clockwise increases flame

American Flame warrants the AF-LMF Valve Kit for 12 months from the date of purchase or installation to the original purchaser 

to be free from defects in materials and workmanship. Damage to the AF-LMF Valve Kit caused by accident, misuse, abuse, 

or installation error, whether preformed by a contractor, Service Company, or owner, is not covered by this warranty. American 

Flame will not be responsible for labor charges and/or damage incurred in installation, repair, replacement, or for incidental or 

consequential damage. Some states, provinces, and nations do not allow exclusion or limitations of incidental or consequential 

damages, so the above limitations or exclusions may not apply. This warranty gives you specific legal rights. You may also have 

other rights that vary by state, province, or nation.

LIMITED WARRANTY

CAUTION:

 Only an experienced service person should be troubleshooting. If not, please call Technical service below.

Содержание AF-LMF

Страница 1: ...uch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppliers instructions If you cannot reach your gas supplier c...

Страница 2: ...its See Figs 2 5 Read the description of each kit to understand how each one operates See each kit below and their contents Fig 2 AF LMF Manual ON OFF gas valve kit Fig 1 Adapter installation ON OF F...

Страница 3: ...line from the valve kit be placed in or over the burner pan 10 Turn ON gas supply and check all connections for leaks using soapy water solution 11 Follow valve pilot lighting instructions After pilot...

Страница 4: ...xceeded The clearance dimensions are from the burner GRATE NOT the burner pan Maintain at least 2 inches from the burner GRATE while keeping the burner pan centered to the grate Never install the valv...

Страница 5: ...curity code upon initial use if batteries are replaced or a replacement transmitter is purchased from your dealer or the factory In order for the receiver to accept the transmitter security code be su...

Страница 6: ...uding provisions for combustion and ventilation air must conform with local codes or in the absence of local codes to the National Fuel Gas Code ANSI Z223 latest addition This product must be on a gas...

Страница 7: ...nector T102 9898 10 7 Damper Clamp 685 14 8 Receiver Shield RS 1A 9 6 volt DC Receiver For AF LMF R AF LMF RV UN3 RX 10 6 volt DC Receiver For AF LMF RVS RCAF 1035RX 11 ON OFF Transmitter For AF LMF R...

Страница 8: ...ck slide switch on the receiver The switch should be in the REMOTE position See Fig 13 4 Check the 4 batteries in the receiver The total voltage of all 4 batteries should not be less than 5 3 volts 5...

Отзывы: