American Flame: AF-LMF Series Valve Kits
Rev. 4-26-21 Page 4
Burner Pan
4.00”
4”
4”
Optional Pilot
Mounting
Pilot Mounting
Valve Kit Box
Burner Pan
Basket Grate
Optional Valve
Mounting Location
2” Min.
2” Min.
2”
Min.
2”
Min.
Fig. 8
Shows clearances to be maintained inside the fire box.
NOTE: VALVE BOX MUST BE LOCATED A MINIMUM OF 2-INCHES FROM SIDE OF THE
BASKET GRATE AND NEVER PLACED DIRECTLY IN FRONT OR BEHIND THE BASKET GRATE
Improper installation or use may overheat the valve and cause malfunction which could result in a dangerous and possibly
deadly gas leak. Overheating the valve kit will also void your warranty.
To avoid overheating:
• The installation clearance dimensions that follow are MINIMUM clearances and must be met or exceeded.
• The clearance dimensions are from the burner GRATE,
NOT
the burner pan. Maintain at least 2-inches from the
burner GRATE while keeping the burner pan centered to the grate.
• Never install the valve kit behind the burner. The valve kit must be installed to the side and to the front of the burner
grate as shown.
• Ensure the orifice supplied by the burner manufacturer or an authorized hearth dealer for the gas type to be used is
installed in the burner. Never remove, drill-out, or use an orifice that increased the rated output of the burner.
• Fully open any solid doors (glass, metal, etc.), open all door vents, and remove any solid barriers from in front of the
fireplace while in operation.
• Ensure chimney flue is open while in operation.
CAUTION
Fig. 6
Shows approximate pilot location from end of the
burner pan.
Fig. 7
Side view of pilot assembly mounted on
edge of burner pan 4-inches from end of pan.
Burner
Pan Lip