american flame AF-LMF Скачать руководство пользователя страница 5

American  Flame: AF-LMF Series Valve Kits

 

Rev. 4-26-21  Page 5

CONNECTING THE REMOTE CONTROL ON AF-LMF-R & AF-LMF-RVS VALVE KITS

1.   The remote control receiver is to be placed next to the valve kit, away from the fire. See Fig 9.

2.   Remove receiver shield and battery cover then install (4) AA alkaline batteries shown in Fig. 11. Reinstall receiver shield.

3.   Connect the red and black wires from the ON/OFF latching solenoid or motor drive on the valve to the red and black wires from the 

remote  receiv er for AF-LMF-R and AF-LMF-RV (Fig. 10).  If installing the AF-LMF-RVS connect the 4-pin connector from the step 

motor to the remote receiver (Fig 12).

4.   Refer to the instructions supplied with the remote control for operation of the remote control.

Note: If you installed a manual gas valve ONLY (without a transmitter and remote receiver) then, disregard the 

information below and go directly to the Lighting Procedures.

Battery 

cover slides on/off

REMOTE

 

ON

OFF

LEARN 

Button

Requires 4-AA 1.5Volts Ea.

(Alkaline batteries)

Slide 

Switch

Fig. 9

 Shows placement of remote receiver for 

protection of radiant heat.

Fig. 11

 Installing batteries into receiver.

Fig. 12

 Step motor connection using 4-PIN connector.

Ensure batteries are installed into the transmitter. Each transmitter uses a unique security code. It may be necessary to 

press the LEARN button on the receiver to accept the transmitter security code upon initial use, if batteries are replaced or 

a replacement transmitter is purchased from your dealer or the factory.  In order for the receiver to accept the transmitter 

security code, be sure the slide button is in the REMOTE position; the receiver will not LEARN if the slide switch is in the 

ON or OFF position.  The LEARN button is located on the front of the receiver inside the small hole labeled LEARN.  Using 

a small screwdriver gently push the black LEARN button inside the hole and release.  When you release the LEARN button 

the receiver will emit a “beep”. After the receiver emits a “beep” press the transmitter ON button and release.  The receiver 

will emit several rapid “beeps” indicating the transmitters code has been accepted into the receiver.

LEARNING TRANSMITTER TO RECEIVER

Note:  

The remote receiver will only respond to the transmitter when 

the 3-position slide switch is in the REMOTE position.  The remote 

receiver houses the microprocessor that responds to commands from 

the transmitter to control the system operation.

Fig. 13 

Remote receiver.

Burner Pan

Basket Grate

AF-LMF Valve Kit

AF-LMF Valve Kit

 AF-LMF 

Remote Control    

Receiver

 AF-LMF 

Remote Control    

Receiver

Back of 

Remote Receiver

BLACK Wire

1/4” Female

Terminal

BLACK Wire

1/4” Male

Terminal

ON

RED Wire

1/4” Female

Terminal

  RED Wire

1/4” Male

Terminal

4-Pin Female

Connector

4-Pin Male 

Connector

4-Pin Female 

Connector

4-Pin Male 

Connector

Receiver Back

Step Motor

Fig. 10

 Solenoid or motor drive connection to receiver.

 

Wire terminals

Remote Receiver

Receiver

Slide

Button

REMOTE

OFF

ON

LEARN

Содержание AF-LMF

Страница 1: ...uch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppliers instructions If you cannot reach your gas supplier c...

Страница 2: ...its See Figs 2 5 Read the description of each kit to understand how each one operates See each kit below and their contents Fig 2 AF LMF Manual ON OFF gas valve kit Fig 1 Adapter installation ON OF F...

Страница 3: ...line from the valve kit be placed in or over the burner pan 10 Turn ON gas supply and check all connections for leaks using soapy water solution 11 Follow valve pilot lighting instructions After pilot...

Страница 4: ...xceeded The clearance dimensions are from the burner GRATE NOT the burner pan Maintain at least 2 inches from the burner GRATE while keeping the burner pan centered to the grate Never install the valv...

Страница 5: ...curity code upon initial use if batteries are replaced or a replacement transmitter is purchased from your dealer or the factory In order for the receiver to accept the transmitter security code be su...

Страница 6: ...uding provisions for combustion and ventilation air must conform with local codes or in the absence of local codes to the National Fuel Gas Code ANSI Z223 latest addition This product must be on a gas...

Страница 7: ...nector T102 9898 10 7 Damper Clamp 685 14 8 Receiver Shield RS 1A 9 6 volt DC Receiver For AF LMF R AF LMF RV UN3 RX 10 6 volt DC Receiver For AF LMF RVS RCAF 1035RX 11 ON OFF Transmitter For AF LMF R...

Страница 8: ...ck slide switch on the receiver The switch should be in the REMOTE position See Fig 13 4 Check the 4 batteries in the receiver The total voltage of all 4 batteries should not be less than 5 3 volts 5...