american flame AF-4000 Series Скачать руководство пользователя страница 9

 

 

 

REV. 4-6-2010   

Page 9 of 11

   

4.  Use the 

Latching Solenoid

 mode when connecting to a Hi/Lo solenoid and the 

DC Motor Drive 

mode when using 

the Hi/Lo DC motor drive. 

5.  When the (AF-4000MOT) Hi/Lo Step Motor is used the 4 pin connector from the step motor connects directly into the 

4 pin AUX connection on the (AF-4000MOD)     

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure #13 

 

 

Direct Spark Ignition Operation (DSI) (optional) 

The AF-4000 series gas valve may be used in conjunction with the AF-5000MOD direct spark ignition control for 
DSI operation. 

1.  For operation with the direct spark ignition control module (AF-5000MOD), both pilot outlets (side and rear) must 

be plugged. 

2.  Follow the AF-5000MOD control instructions for wiring and additional directions on using the AF-4000 series gas 

valve in a direct spark ignition configuration. 

 
 
 
 
 
Fire or explosion hazard. Can cause property damage, severe injury or death. 
 
1.  Stand away from the main burner while lighting, Hidden gas leaks can cause flashbacks in the appliance. 
2.  Check for gas leaks with rich soap and water solution any time work is done on a gas system.   

 

Gas Leak Test 

1.  Paint the pipe connectors upstream of the gas control with rich soap and water solution, Bubbles indicate a gas leak. 
2.  If a leak is detected, tighten the pipe connections. 
3.  Light the main burner. 
4.  With the main burner in operation, paint the pipe joints (including adapters) with rich soap and water solution. 
5.  If another leak is detected, tighten the adapter screws, joints, and pipe conections. 
6.  Replace part if leak cannot be stopped. 

 

(4) Pin AUX Connectors

18”

Battery Pack to Module

     Wiring Harness

RED Wire

Black Wire

1/4” Female

  Terminals

Striped & Tinned

Solenoid or DC motor Drive

         Wiring Harness

HI/LO Connection

   RED Wire

HI/LO Connection

   BLACK Wire

Module Battery Pack Back

4 Pin AUX

Connection

HI/LO Connection

   RED Wire

HI/LO Connection

   BLACK Wire

Module Battery Pack Front

Requires 4-AA 1.5V

alkaline batteries

Module Battery Pack

Bat

tery

 cov

er s

lide

s on

/off

Latching Solenoid

DC Motor Drive

Latching Solenoid

DC Motor Drive

 

f i r e - p a r t s . c o m

Содержание AF-4000 Series

Страница 1: ...ith High Low Variable DC Motor Drive Remote 4 With High Low Step Motor Model AF 4000MOT Type of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Moun...

Страница 2: ...s Side Back of valve Ambient Temperature Range 0 0 F to 175 0 F 18 0 C to 79 0 C Voltage 6 Volt DC Powered Approvals CSA International Valve Report Number 224930 1546330 Module Report Number 224930 19...

Страница 3: ...REV 4 6 2010 Page 3 of 11 DIMENSIONS fire parts com...

Страница 4: ...hnician Force or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 4000 gas control where it cannot be affected by steam cleaning high humidity drippin...

Страница 5: ...re 4 1 Unscrew and remove the cover cap Note the position of the marker on the shaft of the Simple Rotary knob This mark will point to NAT or LP that indicates the type of gas the valve is set on 2 To...

Страница 6: ...onic control valve is eqiuped with a HI LO solenoid HI LO DC motor drive or HI LO Step Motor locate the wiring connections on the HI LO device Note Figure 8 Figure 7 Figure 8 Wiring The AF 4000 MOD Mo...

Страница 7: ...6 volt transformer to the 2 1 4 male terminals marked POWER on the module Note location on Figure 11 Optional If an AF 4000 BP battery pack is used follow the Wiring The AF 4000 BP Battery Pack secti...

Страница 8: ...DC adaptor This adaptor is connected to the AF 4000 MOD by connecting the 2 1 4 female terminals from the adaptor to the 2 1 4 male terminals located on the AF 4000 MOD marked power Using the 6 0 volt...

Страница 9: ...dden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution any time work is done on a gas system Gas Leak Test 1 Paint the pipe connectors upstream of...

Страница 10: ...assembly and cleaning can cause unreliable operation Regular preventive maintenance is important in applications that place a heavy load on the system such as those used in commerical cooking agricul...

Страница 11: ...F 4000 MOD module 3 Check the power sorce 1 the 6 volt power adaptor or the AF 4000 BP battery pack connections and condition of batteries 4 Optional check the position of the CONTINUOUS PILOT switch...