2.  When the continuous pilot switch is in the OFF position and the appliance on/off switch is turned ON the pilot will 

spark and light, and when the appliance on/off switch is turned OFF the pilot will shut OFF when the main burner 
shuts OFF. 

3.  When the continuous pilot switch is in the ON position and the appliance on/off switch is turned ON the pilot will spark 

and light, when the appliance on/off switch is turned OFF the pilot will stay ON when the main burner shuts OFF. This 
setting is generally used in Cold Climate to keep the firebox warm.  

4.  The CONTINUOUS pilot mode can also be activated by an (Optional) hand held Remote Control. 
  

 
REMOTE CONTROL FEATURE:

 The (AF-4000 MOD) module has a built in remote control receiver this allows the user 

to program a hand held remote transmitter, wireless wall mount thermostat or wireless wall mount switch to the appliance 
at any time during or after installation of the appliance. 
1.  There is a switch located on the right side of the (AF-4000 MOD) module that reads REMOTE/OFF. Note: Figure #9 
2.  When the remote/off switch is in the OFF position the appliance will operate from an appliance mounted rocker switch 

or wall switch connected to the (2) BROWN wires on the (AF-4000 MOD) Module. 

3. 

When the remote/off switch is in the REMOTE position the appliance will operate from the (Optional) Remote Control 
transmitter wireless wall mount thermostat or wireless wall mount switch.

 

Note: 

The AF-4000 MOD must be programmed to the (Optional) Remote Control transmitter wireless wall mount 

thermostat or wireless wall mount switch. 
1.  To program the AF-4000 MOD (Make sure the system is power) locate the learn button on the AF-4000 MOD (Note 

Figure #10) press and release the learn button there will be a beep sound from the AF-4000 MOD then press any key 
on the remote transmitter. Once the AF-4000 MOD internal receiver accepts the transmitter code there will be a series 
of confirming beeps. 

2. 

The remote system is ready for use.

 

 

AF-4000 MOD (Options) 

The AF-4000 MOD can be powered by two (2) different scores (1) is a standard 110 volt AC to 6.0 volt DC adaptor. This 
adaptor is connected to the AF-4000 MOD by connecting the (2) 1/4’ female terminals from the adaptor to the (2) 1/4” 
male terminals located on the AF-4000 MOD marked (power). 
Using the 6.0 volt adaptor (only) without using the AF-4000 BP battery pack the system will not have a back up power 
scores during a power outages.   
 

 
Wiring The (AF-4000 BP) Battery Pack 

1.  Locate the (AF-4000 BP) battery pack in an area that that will not exceed an ambient temperature of 130º F (Batteries 

exposed to temperatures above 120ºF will drain voltage and shorten battery life). 

2.  Locate the AUX connection and the optional Hi/Lo wire connections on the (AF-4000 BP) battery pack Note: Figure 

#13. 

3.  Locate the wire connections on the (4) pin connector wiring harness and the solenoid or DC motor drive wiring 

harness shown in Note Figure #13. 

4.  Install (4) AA alkaline batteries in the (AF-4000 BP) battery pack. 
5.  Plug one of the (4) pin female connector on the (AF-4000 BP) battery pack wiring harness into the (4) pin male 

connector located on the back of the battery pack Note location shown in Figure #13. 

6.  Plug the other (4) pin male connector on the (AF-4000 BP) battery pack wiring harness into the (4) pin female AUX 

connector located on the (AF-4000 MOD) module shown Note location shown in Figure #10. 

7.  If the model of AF-4000 electronic control valve has a Hi/Lo solenoid or DC motor drive use the solenoid or DC motor 

drive wiring harness shown in Figure #13 

 

Note

:  

If the Hi/Lo Step Motor (Model AF-4000MOT) has been selected the this requires a unique operating 

control transmitter and receiver specifically set-up for the desired Hi/Lo increments required by the burner 
installed in the appliance that the AF-4000 valve system is used on.   

 
Wiring The Optional Hi/Lo  

1.  Connect the striped ends of the RED and BLACk wires on solenoid or DC motor drive wiring harness to the screw 

terminals located on ther top of the (AF-4000 BP) battery pack Note: location in Figure #13 

2.  Connect the (2) 1/4” female terminals on the solenoid or DC motor drive wiring harness to the matching color (RED & 

BLACK) 1/4” male terminals on the Hi/Lo solenoid or the Hi/Lo DC motor drive. Note: locations in Figure #8 & #13.  

3.  Note the Latching Solenoid mode and DC Motor Drive mode switch located on the front of the (AF-4000 BP) battery 

pack in Figure #13. 

f i r e - p a r t s . c o m

Содержание AF-4000 Series

Страница 1: ...ith High Low Variable DC Motor Drive Remote 4 With High Low Step Motor Model AF 4000MOT Type of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Moun...

Страница 2: ...s Side Back of valve Ambient Temperature Range 0 0 F to 175 0 F 18 0 C to 79 0 C Voltage 6 Volt DC Powered Approvals CSA International Valve Report Number 224930 1546330 Module Report Number 224930 19...

Страница 3: ...REV 4 6 2010 Page 3 of 11 DIMENSIONS fire parts com...

Страница 4: ...hnician Force or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 4000 gas control where it cannot be affected by steam cleaning high humidity drippin...

Страница 5: ...re 4 1 Unscrew and remove the cover cap Note the position of the marker on the shaft of the Simple Rotary knob This mark will point to NAT or LP that indicates the type of gas the valve is set on 2 To...

Страница 6: ...onic control valve is eqiuped with a HI LO solenoid HI LO DC motor drive or HI LO Step Motor locate the wiring connections on the HI LO device Note Figure 8 Figure 7 Figure 8 Wiring The AF 4000 MOD Mo...

Страница 7: ...6 volt transformer to the 2 1 4 male terminals marked POWER on the module Note location on Figure 11 Optional If an AF 4000 BP battery pack is used follow the Wiring The AF 4000 BP Battery Pack secti...

Страница 8: ...DC adaptor This adaptor is connected to the AF 4000 MOD by connecting the 2 1 4 female terminals from the adaptor to the 2 1 4 male terminals located on the AF 4000 MOD marked power Using the 6 0 volt...

Страница 9: ...dden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution any time work is done on a gas system Gas Leak Test 1 Paint the pipe connectors upstream of...

Страница 10: ...assembly and cleaning can cause unreliable operation Regular preventive maintenance is important in applications that place a heavy load on the system such as those used in commerical cooking agricul...

Страница 11: ...F 4000 MOD module 3 Check the power sorce 1 the 6 volt power adaptor or the AF 4000 BP battery pack connections and condition of batteries 4 Optional check the position of the CONTINUOUS PILOT switch...

Отзывы: