american flame AF-4000 Series Скачать руководство пользователя страница 2

 

 

 

REV. 4-6-2010   

Page 2 of 11

   

 
 
 

 
 TABLE #1 

 

AF-4000 VOLTAGE / CAPACITY RATINGS 

 

 

 Model  

Position 

 Internal Solenoids  

Capacity@ 1” Pressure Drop Capacity@ 1” Pressure Drop 

 

 

 

 

 

 

 

 

    Side inlet & outlet 

           Back inlet & outlet 

 

          

All Models

   

Multi positional            6 Volt DC 

  50,000 BTU/hr 

 

50,000 BTU/hr 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

 

 

Main Gas Connections:

 

 

 

Valve: 3/8 in. NPT thread on all Inlet and Outlet connections. 

 

 

 

 

 

 

Optional 1/2"NPT Side Inlet and Outlet 

 

Pilot Gas connections and flow:

 

 

Connection Size: 7/16-24 UNS. 

 

 

 

 

 

 

Flow:  ~ 5,250 Btu/hr at 7.0 in wc Maximum. 

Pilot locations:  

 

 

 

Side & Back of valve

 

Ambient Temperature Range:

   

 

0

0

 F to 175

0

 F (-18

0

 C to 79

0

 C) 

 

Voltage:

 

 

 

 

 

6 Volt DC Powered 

 

Approvals: 

 

 

 

 

CSA International 

 

 

 

 

 

 

Valve: Report Number  224930-1546330 

 

 

 

 

 

 

Module: Report Number 224930-1998843 

 

 

 

Model / Voltage / Capacity: 

 

 

Reference Table #1 

 
 
 
 

 

40

60

80

100

120

140

160

AF-4000 Series Gas Control

Pressure Drop & Capacity Curve

Btu/hr  X 1K

Pressure

   Drop

  in.  w.c

2.0” Inlet @ 1.0” outlet = 1.0” pressure drop

3.0” Inlet @ 1.5” outlet = 1.5” pressure drop

4.0” Inlet @ 2.0” outlet = 2..0” pressure drop

7.0” Inlet @ 3.5 outlet  = 3.5” Pressure drop

6.0” Inlet @ 3.0” outlet = 3.0” pressure drop

5.0” Inlet & 2.5” outlet = 2.5” pressure drop

This information is American Flame lab generated data and is to be used as reference only.

 

f i r e - p a r t s . c o m

Содержание AF-4000 Series

Страница 1: ...ith High Low Variable DC Motor Drive Remote 4 With High Low Step Motor Model AF 4000MOT Type of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Moun...

Страница 2: ...s Side Back of valve Ambient Temperature Range 0 0 F to 175 0 F 18 0 C to 79 0 C Voltage 6 Volt DC Powered Approvals CSA International Valve Report Number 224930 1546330 Module Report Number 224930 19...

Страница 3: ...REV 4 6 2010 Page 3 of 11 DIMENSIONS fire parts com...

Страница 4: ...hnician Force or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 4000 gas control where it cannot be affected by steam cleaning high humidity drippin...

Страница 5: ...re 4 1 Unscrew and remove the cover cap Note the position of the marker on the shaft of the Simple Rotary knob This mark will point to NAT or LP that indicates the type of gas the valve is set on 2 To...

Страница 6: ...onic control valve is eqiuped with a HI LO solenoid HI LO DC motor drive or HI LO Step Motor locate the wiring connections on the HI LO device Note Figure 8 Figure 7 Figure 8 Wiring The AF 4000 MOD Mo...

Страница 7: ...6 volt transformer to the 2 1 4 male terminals marked POWER on the module Note location on Figure 11 Optional If an AF 4000 BP battery pack is used follow the Wiring The AF 4000 BP Battery Pack secti...

Страница 8: ...DC adaptor This adaptor is connected to the AF 4000 MOD by connecting the 2 1 4 female terminals from the adaptor to the 2 1 4 male terminals located on the AF 4000 MOD marked power Using the 6 0 volt...

Страница 9: ...dden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution any time work is done on a gas system Gas Leak Test 1 Paint the pipe connectors upstream of...

Страница 10: ...assembly and cleaning can cause unreliable operation Regular preventive maintenance is important in applications that place a heavy load on the system such as those used in commerical cooking agricul...

Страница 11: ...F 4000 MOD module 3 Check the power sorce 1 the 6 volt power adaptor or the AF 4000 BP battery pack connections and condition of batteries 4 Optional check the position of the CONTINUOUS PILOT switch...

Отзывы: