American Energy Systems Avent Скачать руководство пользователя страница 9

 

9

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

It is recommended that only an authorized Avent Wood Pellet installer install your wood pellet stove.

  The following 

installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building 
codes. 
 

9

 

A listed 3” or 4” type “PL” pellet vent exhaust system must be used for FREESTANDING installation and attached to the 
pipe connector provided on the top of the stove.  Use a 3” to 4” adapter for 4” pipe.  A cap must be used at the termination 
of type “L” vent chimneys.  Existing approved 4, 6 and 8” wood stove pipe may be used with adaptors to 3 inch pellet vent 
pipe as shown in the installation instructions. The pipe adaptors must be provided by the venting manufacturer. 

 

9

 

Do not terminate vent in any 

enclosed or semi-enclosed

 area, such as; carports, garage, attic, crawl space, under a sundeck 

or porch, narrow walkway or closed area, or any location that can build up a concentration of fumes such as a stairwell, 
covered breezeway etc. 

 

9

 

Vent surfaces can get hot enough to cause burns if touched by children.  Non-combustible  shielding or guards may be 
required.  

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENT OF THIS UNIT. 

 

9

 

Termination must exhaust above air inlet elevation. 

 It is required that at least 5 ft. of vertical pipe be installed when 

the appliance is vented directly through a wall or in a basement.

  This will create some natural draft to prevent the 

possibility of smoke or odor during appliance shutdown and to keep exhaust from causing a nuisance or hazard from 
exposing people or shrubs to high temperatures.  In any case, the safest and preferred venting method is to extend the vent 
through the roof.  

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. 

GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN 

28” 

6” 
min. 

HEARTH PROTECTION 

The side and top clearance are to be used when 

installing the Avent Wood Pellet stove into an alcove 

as shown to the left and below. 

Minimum Alcove Height is 56” 

(1425mm) 

Maximum Alcove Depth is 36” 

(915mm) 

Minimum Alcove width is 27.5” 

(700mm) 

28” 

14”

Содержание Avent

Страница 1: ...etal container with a tight fitting lid 9 All minimum clearances to combustibles must be followed 9 The Avent Wood Pellet Stove is tested for operation with wood pellets with ash content of no more th...

Страница 2: ...OME INSTALLATION REQ 14 ALCOVE FREE STANDING STOVE INSTALLATION REQUIREMENTS 15 17 GLASS MAINTENANCE ADJUSTMENT REMOVAL AND REPLACEMENT 17 CLEANING THE GLASS STOVE CONTROLS 18 19 PRIMING LIGHTING OPER...

Страница 3: ...s lacking of good quality air in the home caused by negative pressure If you have done any remodeling or if this is a newer home it is a very real possibility that this is happening Most basements hav...

Страница 4: ...dapt to different size fuels and consumption circumstances If you are experiencing different feed rates than shown you will need to set the fuel feed rate on a lower or higher setting to adjust for th...

Страница 5: ...l rewards available and I encourage you to ask your local dealer how to get involved in helping make our country energy self sufficient GOOD LUCK American Energy Systems Inc manufacturer of the Avent...

Страница 6: ...approved for this appliance it will void the warranty and no service warranty will be allowed The Avent will burn high ash content fuels but will require additional maintenance cleaning 9 A working sm...

Страница 7: ...nt in your wood pellet fuel supplier Wood Pellets will vary in content and burn characteristics from supplier to supplier A consistent supply of wood pellets will require fewer adjustments to the draf...

Страница 8: ...unit with the staples Remove the wood blocks and plastic We strongly urge you to recycle the packaging materials to help protect the environment The Avent Wood Pellet Freestanding Stove may be instal...

Страница 9: ...ion of fumes such as a stairwell covered breezeway etc 9 Vent surfaces can get hot enough to cause burns if touched by children Non combustible shielding or guards may be required DO NOT INSTALL A FLU...

Страница 10: ...gle wall stainless exhaust system must be installed so as to be GAS TIGHT The vent manufacturer s installation procedures must be followed In addition pipe connections joints and all pipe seams within...

Страница 11: ...nt pipe length should not exceed 20 feet Component Equivalent Length Equivalent Pipe Length Horizontal Straight Pipe Actual Length in ft x 1 0 Horizontal Pipe 1 x 2 1 3 ft Vertical Straight Pipe Actua...

Страница 12: ...e tubing be non combustible materials but is not required 4 If the air inlet is connected to the outside it MUST be terminated with a vertical 90 degree bend down or with a wind hood Failure to do so...

Страница 13: ...is located on the back panel of the pedestal fan housing WARNING DO NOT RESTRICT OR OTHERWISE COVER THE FAN INTAKE EXCEPT AS SHOWN FOR THE OUTSIDE AIR HOOKUP The outside air must be directly connecte...

Страница 14: ...ermanently bolted to the floor 2 Stove must have permanent outside air source 3 Stove must be permanently electrically ground to the steel chassis of the mobile home 4 All vertical chimney vent must h...

Страница 15: ...STALLATION REQUIREMENTS Limited Horizontal Exhaust Termination 1 Position stove on the noncombustible floor pad with the proper clearances to combustibles and in the location that you have determined...

Страница 16: ...tructions should be followed for the brand of venting being used Before drilling or cutting holes select the proper location of the appliance Determine location of combustibles ceiling rafters wall st...

Страница 17: ...an authorized Avent Wood Pellet reseller if it needs to be replaced Reverse the above procedure for replacing new glass When installing the new glass make sure that the glass is binding anywhere in th...

Страница 18: ...12 volt DC wiring installation The Avent pellet stove is designed to operate on a 12 volt DC battery system for extended back up periods This system may also be used in conjunction with 12 volt solar...

Страница 19: ...ermostat Jumper factory Installed back of board The ash rake should not be left in the unit when operating If you do make sure that it is pushed all the way to the back of the unit and there is no bui...

Страница 20: ...approximately inch more or less if necessary 9 Once the wood pellets are burning good set the power switch to the on position and adjust the manual draft knob located on the right side of the unit so...

Страница 21: ...he unit down simply move the power switch to the off position and the system will enter the shut down mode The room fan exhaust blower will continue to operate until the low limit safety censor tells...

Страница 22: ...cated on the left and right side of the firepot remove the ash buckets and empty them Remove the firepot and clean out any fly ash and make sure that all holes are open A small screwdriver works well...

Страница 23: ...clean out all of the fuel in the hopper firebox area ash pan and firepot area It is recommended that prior to shutting down the unit in the spring run the unit on the higher settings for a day to hel...

Страница 24: ...home or the make up air for the unit will be sucked out of the unit and into the home First evidence of this happening is fly ash or soot in the home or smoke coming out of the unit A quick test to se...

Страница 25: ...cross wires with circuitry on board You can route the wires through where the AC cord enters the unit on the back 9 Reinstall in reverse procedure When using a wall thermostat set the appliance heat s...

Страница 26: ...stranded wire to black terminal on back of stove Pass wires through conduit leaving room for a drip loop between connections so that moisture will not get on connections Install a 4 amp inline fuse on...

Страница 27: ...ange to a better grade of fuel if necessary 9 Remove any clinkers or ash from the firepot 9 Clean out primary air holes in firepot if plugged 9 Check gasket seal around the door If the door is loose a...

Страница 28: ...d pressure switch or relay 9 Check contents of the hopper Add fuel if necessary 9 Have your Avent Wood Pellet reseller diagnose the problem and replace the parts Stove runs for 10 minutes and then shu...

Страница 29: ...draft control out slightly to make sure that there is app inch of fuel in firepot 9 Install outside air to unit and make sure that the home has adequate make up air suggested 6 make up air into baseme...

Страница 30: ...e 3 or high setting and turn the adjustable resistor H clockwise to increase the burn rate and counter clockwise to decrease the burn rate Note Fan voltages are fixed and ay not be adjusted The Medium...

Страница 31: ...rranty is limited to the repair or replacement of the covered defective part The purchaser shall assume all costs related to shipping the replacement parts or return of the unit to the factory for rep...

Страница 32: ...32 SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED This record must be sent in when any warranty claims are made...

Отзывы: