American Energy Systems Avent Скачать руководство пользователя страница 20

 

20

 
 
 
 
 
 
 

NOTE: This appliance is designed to burn premium wood pellets, olive pits or cherry pits.  Do not burn corn 
or any other fuel.  Do not overfire this appliance. Do not bypass any safety or operational switches. Over 
firing this appliance will cause damage to the heat exchangers, and cause the safety switches to shut the 
appliance down.  Over firing can be caused by excessive positive pressure in the home.  This must be 
corrected. 

 

Priming the Auger System:  Never leave the appliance unattended while priming the auger system 
or during startup of the unit.  Priming the auger will be necessary if the hopper has run out of fuel 
or you are starting the unit for the first time. 
Procedure: 

Load the hopper with wood pellets, Set the power switch to the “on” position. 

Note: This is 

the low fan/burn speed when the appliance is operating. 

Press the “start/manual feed” button and hold the button down for approximately 2-3 minutes or until 
pellets begin to feed.  The auger light will come on, indicating that the auger motor is running. 

Note: 

When the pellets begin to drop regularly, the auger is primed.  Allow the pellets to accumulate in 
the firepot until one even layer of fuel is in the firepot.  The start button may now be released. 

Set the power switch to the “off” position. 
 

Starting the Avent Pellet Stove:  Note: Each time the appliance is started, the firepot should be 
checked for debris and clear the air holes.  Do not allow ash to build up underneath the firepot. 
If there are not any pellets in the firepot from priming, add app. ½” of fuel to the firepot. 

Open the door and add a small amount of fire starter gel (Evenly across the wood pellets)on top of the wood 
pellets. (app. ½” of fuel) Light the fire starter and wait app. 1-minute for it to start burning.  Close the door. 

 

9

 

Pull out the manual draft knob approximately ¼ inch. (more or less if  necessary) 

 

9

 

Once the wood pellets are burning good set the power switch to the “on” position and adjust the manual draft 
knob (located on the right side of the unit so that there is approximately ½ inch of fuel in the bottom of the 
firepot.  This level cannot be determined quickly.  Minor adjustments will have to be made until the main fuel 
starts coming in and the unit is up to temperature.  

The heat selector switch should be on the med. Setting.

 

 

9

 

Let the fire continue to build for approximately 1-2 minutes, then press the “start/manual feed button 
momentarily and release.  

Note:  The green power light will come on, indicating that the auger timer is 

energized.  

If the firepot begins to fill up with unburned fuel, open the manual draft knob a little to burn up the 

excess fuel.  If the fire is going out because there is too much fuel coming in, adjust the manual air damper in a 
little until the fire load is balanced.  Small adjustments to the air setting will give the best results.

 

 

9

 

Once the fire has established itself (usually 10 to 15 minutes) select the low, med or high setting and adjust the 
manual draft knob so that there is approximately ½ inch of fuel in the bottom of the firepot. 

Do not let the fuel 

build up any higher than that or it will cause the fire to burn dirty and you will get excessive ash.  If the 
fuel level is too low (below ¼”) the fire may go out. 

 

9

 

The air damper setting will vary with fuel, venting and weather conditions.  Adjustments will need to be 
made periodically to maintain a balanced fire. 

 

PRIMING / LIGHTING / OPERATING INSTRUCTIONS 

Before lighting your 

Avent Wood Pellet

 

Stove 

for the first time make sure that all items are out of the hopper 

and firebox area.  Turn the heat setting to the off position and push the manual draft in as far as it will go.  

Note: 

If using a wall thermostat option make sure that the thermostat is turned up above room temperature.  

The unit will operate on low fire if the thermostat is turned down

.  

Содержание Avent

Страница 1: ...etal container with a tight fitting lid 9 All minimum clearances to combustibles must be followed 9 The Avent Wood Pellet Stove is tested for operation with wood pellets with ash content of no more th...

Страница 2: ...OME INSTALLATION REQ 14 ALCOVE FREE STANDING STOVE INSTALLATION REQUIREMENTS 15 17 GLASS MAINTENANCE ADJUSTMENT REMOVAL AND REPLACEMENT 17 CLEANING THE GLASS STOVE CONTROLS 18 19 PRIMING LIGHTING OPER...

Страница 3: ...s lacking of good quality air in the home caused by negative pressure If you have done any remodeling or if this is a newer home it is a very real possibility that this is happening Most basements hav...

Страница 4: ...dapt to different size fuels and consumption circumstances If you are experiencing different feed rates than shown you will need to set the fuel feed rate on a lower or higher setting to adjust for th...

Страница 5: ...l rewards available and I encourage you to ask your local dealer how to get involved in helping make our country energy self sufficient GOOD LUCK American Energy Systems Inc manufacturer of the Avent...

Страница 6: ...approved for this appliance it will void the warranty and no service warranty will be allowed The Avent will burn high ash content fuels but will require additional maintenance cleaning 9 A working sm...

Страница 7: ...nt in your wood pellet fuel supplier Wood Pellets will vary in content and burn characteristics from supplier to supplier A consistent supply of wood pellets will require fewer adjustments to the draf...

Страница 8: ...unit with the staples Remove the wood blocks and plastic We strongly urge you to recycle the packaging materials to help protect the environment The Avent Wood Pellet Freestanding Stove may be instal...

Страница 9: ...ion of fumes such as a stairwell covered breezeway etc 9 Vent surfaces can get hot enough to cause burns if touched by children Non combustible shielding or guards may be required DO NOT INSTALL A FLU...

Страница 10: ...gle wall stainless exhaust system must be installed so as to be GAS TIGHT The vent manufacturer s installation procedures must be followed In addition pipe connections joints and all pipe seams within...

Страница 11: ...nt pipe length should not exceed 20 feet Component Equivalent Length Equivalent Pipe Length Horizontal Straight Pipe Actual Length in ft x 1 0 Horizontal Pipe 1 x 2 1 3 ft Vertical Straight Pipe Actua...

Страница 12: ...e tubing be non combustible materials but is not required 4 If the air inlet is connected to the outside it MUST be terminated with a vertical 90 degree bend down or with a wind hood Failure to do so...

Страница 13: ...is located on the back panel of the pedestal fan housing WARNING DO NOT RESTRICT OR OTHERWISE COVER THE FAN INTAKE EXCEPT AS SHOWN FOR THE OUTSIDE AIR HOOKUP The outside air must be directly connecte...

Страница 14: ...ermanently bolted to the floor 2 Stove must have permanent outside air source 3 Stove must be permanently electrically ground to the steel chassis of the mobile home 4 All vertical chimney vent must h...

Страница 15: ...STALLATION REQUIREMENTS Limited Horizontal Exhaust Termination 1 Position stove on the noncombustible floor pad with the proper clearances to combustibles and in the location that you have determined...

Страница 16: ...tructions should be followed for the brand of venting being used Before drilling or cutting holes select the proper location of the appliance Determine location of combustibles ceiling rafters wall st...

Страница 17: ...an authorized Avent Wood Pellet reseller if it needs to be replaced Reverse the above procedure for replacing new glass When installing the new glass make sure that the glass is binding anywhere in th...

Страница 18: ...12 volt DC wiring installation The Avent pellet stove is designed to operate on a 12 volt DC battery system for extended back up periods This system may also be used in conjunction with 12 volt solar...

Страница 19: ...ermostat Jumper factory Installed back of board The ash rake should not be left in the unit when operating If you do make sure that it is pushed all the way to the back of the unit and there is no bui...

Страница 20: ...approximately inch more or less if necessary 9 Once the wood pellets are burning good set the power switch to the on position and adjust the manual draft knob located on the right side of the unit so...

Страница 21: ...he unit down simply move the power switch to the off position and the system will enter the shut down mode The room fan exhaust blower will continue to operate until the low limit safety censor tells...

Страница 22: ...cated on the left and right side of the firepot remove the ash buckets and empty them Remove the firepot and clean out any fly ash and make sure that all holes are open A small screwdriver works well...

Страница 23: ...clean out all of the fuel in the hopper firebox area ash pan and firepot area It is recommended that prior to shutting down the unit in the spring run the unit on the higher settings for a day to hel...

Страница 24: ...home or the make up air for the unit will be sucked out of the unit and into the home First evidence of this happening is fly ash or soot in the home or smoke coming out of the unit A quick test to se...

Страница 25: ...cross wires with circuitry on board You can route the wires through where the AC cord enters the unit on the back 9 Reinstall in reverse procedure When using a wall thermostat set the appliance heat s...

Страница 26: ...stranded wire to black terminal on back of stove Pass wires through conduit leaving room for a drip loop between connections so that moisture will not get on connections Install a 4 amp inline fuse on...

Страница 27: ...ange to a better grade of fuel if necessary 9 Remove any clinkers or ash from the firepot 9 Clean out primary air holes in firepot if plugged 9 Check gasket seal around the door If the door is loose a...

Страница 28: ...d pressure switch or relay 9 Check contents of the hopper Add fuel if necessary 9 Have your Avent Wood Pellet reseller diagnose the problem and replace the parts Stove runs for 10 minutes and then shu...

Страница 29: ...draft control out slightly to make sure that there is app inch of fuel in firepot 9 Install outside air to unit and make sure that the home has adequate make up air suggested 6 make up air into baseme...

Страница 30: ...e 3 or high setting and turn the adjustable resistor H clockwise to increase the burn rate and counter clockwise to decrease the burn rate Note Fan voltages are fixed and ay not be adjusted The Medium...

Страница 31: ...rranty is limited to the repair or replacement of the covered defective part The purchaser shall assume all costs related to shipping the replacement parts or return of the unit to the factory for rep...

Страница 32: ...32 SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED This record must be sent in when any warranty claims are made...

Отзывы: