SPEEDDOME ULTRA OUTDOOR HOUSING
8200-0184-10, REV. C
CONTINUATION OF INSTALLATION GUIDE
6 of 12
Connector Pin Assignments
GREEN CONNECTOR (POWER)
Pin Color Description
1 N/A 24Vac
2 N/A EMI
ground
3 N/A 24Vac
BLACK CONNECTOR (DATA)
Manchester
Pin Color* Designation
1-4 —
Not
used.
5 Black
Manchester
(+)
6 White
Manchester
(–)
RS-422 / SensorNet
Pin Color* Designation
1
Orange
RS-422 Data In High (+)
2
Green
RS-422 Data In Low (–)
3
Yellow
RS-422 Data Out High (+)
4
Brown
RS-422 Data Out Low (–)
5 Brown
SensorNet
(unshielded)
6
Yellow
SensorNet (unshielded)
*Color based on composite cable.
GRAY CONNECTOR (RELAY OUTPUTS)
Pin Color Description
1 N/A Normally
Closed
2 N/A Relay
armature
3
N/A
Normally Open (3.5mA sink)
4 N/A Alarm
Return
5
N/A
Alarm input (3.5mA sink)
BLUE CONNECTOR (ALARM)*
Pin Color Designation
1
N/A
Alarm input (3.5mA sink)
2
N/A
Alarm input (3.5mA sink)
3
N/A
Alarm input (3.5mA sink)
4 N/A Alarm
Return
* -02 housings only. 0100-2468-02 standard
housing, 0101-0061-02 vandal-resistant
housing.
Cable Requirements
Data Cable
The table below shows requirements for
SensorNet, RS-422, and Manchester networks. For
more information about communication protocols
and cable networks, see Communication Protocols
and Cable Networks, 8000-2573-19.
Data cable requirements
SensorNet
RS-422
Manchester
Cable type
1
unshielded,
twisted
pair*
2
shielded,
twisted
pair*
1
shielded
twisted
pair**
Wire gauge
22 AWG
22 AWG
18 AWG
Connection Non-
polarized
Polarized Polarized
Max.
devices on
line
32 10
3
* Power, data, and video cables can be ordered
separately or within a composite cable that can be
ordered in various lengths. Plenum-rated cables
must be used in indoor ceilings used for environ-
mental air return (called "other air space" in the
National Electrical Code). Order parts through
your distribution network.
Note:
If you order cable from an outside
source, wire colors may be different.
** Belden 88760 (plenum), or Belden 8760 cable
(non-plenum) cable is recommended. Plenum-
rated cables must be used in indoor ceilings used for
environmental air return (called "other air space" in
the National Electrical Code). Order
cable directly
from Belden by calling 1-800-235-3361.
Power Cable
The camera dome and housing are to be
connected to a Class 2 LPS, 24Vac, 80VA power
source. Do not exceed the maximum outdoor Class
2 ratings of 30Vac, 100VA.
18AWG 16AWG 14AWG
Low Line Voltage
102/204 Vac
60m
(200ft)
100m
(320ft)
160m
(520ft)
Low Line Voltage
90/180 Vac
30m
(100ft)
50m
(160ft)
80m
(260ft)