American Dynamics RHODUL-03E Скачать руководство пользователя страница 11

 

SPEEDDOME ULTRA OUTDOOR HOUSING 

8200-0184-10, REV. C 

CONTINUATION OF INSTALLATION GUIDE 

11 of 12

 

Ice Forms on Bubble 

Follow steps until the problem is corrected. See 
page 5

 

to order parts. 

1.  Are fans in the housing are working? If not, see 

“Fans Do Not Turn” opposite. 

2.  Is the camera dome receiving power? Look for 

evidence such as a picture on the video monitor 
or dome movement. 

3.  Detach the dome to access the environmental 

PC board. 

Note:

 Power to the heater comes from the 

dome. The heater will not function with the 
dome removed. 

CAUTION:

 Touch the metal housing before 

handling the PC board. 

4.  Verify power is reaching the housing. Press and 

hold switch SW2 and observe the green (ac 
power) LED; it should glow steadily. If not, 
check power at the J-box and if the ac cable is 
plugged into connector P7 on other side of 
environmental PC board. 

CAUTION:

 Use a 2.5mm (0.1in) slotted 

screwdriver. Using a blade too wide can 
damage connectors. 

CAUTION:

 Screws on the ac connector are 

delicate. DO NOT over tighten them! 

5.  Check the heater connector on other side of the 

environmental PC board. Is it plugged into 
connector P2? 
-  YES: Unplug the heater cable and check 

heater resistance across pins of plug. Is the 
resistance approximately 16 ohms? 
If yes, replace environmental PC board 
0301-0949-01. If not, replace fan/heater 
assembly 0400-0935-01 by removing the two 
screws. 

-  NO: Plug the connector in, reinstall the 

environmental PC board, and reattach the 
dome. If the fans still do not work, replace 
the fan/heater assembly. 

Specifications 

Electrical (combined dome and housing) 

Input Voltage .............................. 24 to 30Vac, 50/60 Hz  

UL Listed Class 2  
Certified Limited Power Source 

Design Tolerance ....................... 20 to 36Vac, 50/60 Hz 
Power Consumption ................... 80W max. 
Power On In-Rush current.......... 3A 

Surge Protection: 

Video .......................................... Series resistor of 3.9 ohms; 

low-capacitance Zener 
suppressor of 6.5V, 1500W, 
500W, 10kA impulse-rated gas 
tube 

Power Line.................................. TVS rated at 60V, 1.5 joules, 

250A 8/20µs impulse, 500W, 
10kA impulse-rated gas tube 

RS-422 ....................................... Series resistor of 3.3 ohms; 

TVS rated at 5.6V, 40A, 0.1 
joules, 8/20µs impulse, 500W, 
10kA impulse-rated gas tube 

Manchester/SensorNet............... Isolation transformer coupled 

2000Vrms; PTC fuse protects 
transformer; TVS rated at 
5.6V, 40A, 0.1 joules, 8/20µs 
impulse, 500W, 10kA impulse-
rated gas tube 

Alarm Input ................................. Series resistors of 33 ohms; 

TVS rated at 5.6V, 40A, 0.1 
joules, 8/20µs impulse, 500W, 
10kA impulse-rated gas tube 

Auxiliary Output .......................... 1000V Isolation Form 1-C 

relay 

Environmental 

Operating Temperature .............. –40°C to 50°C 

(–40°F to 122°F) 

Relative Humidity........................ 0 to 95% non-condensing 
Storage Temperature ................. –10°C to 50°C 

(–14°F to 122°F) 

Wind loading............................... Sustained winds of 

240Km/hour (150 miles/hour) 
when properly installed and 
mounted (wall, pole, ceiling, 
and over-the-roof mount with 
proper support) 

Mechanical 

Height ......................................... 32.1cm (12.6in) 
Diameter ..................................... 24.4cm (9.6in) 
Weight: 
Without dome ............................. 2.7kg (6.1 lbs.) 
With dome .................................. 3.9kg (8.7 lbs.) 
Mechanical connection............... 1.5in NPT 

Содержание RHODUL-03E

Страница 1: ... housing to mounting structure Attach cable connectors 0100 2468 02 Standard Housing 0101 0061 02 Vandal Resistant Housing Blue alarm connector used with 02 housings only Pin 1 24Vac Pin 2 EMI Ground Pin 3 24Vac Pin 1 White Blue Alarm 2 3 5mA sink Pin 2 White Brown Pin 3 White Purple Pin 4 White Red Alarm Return Alarm 3 3 5mA sink Alarm 4 3 5mA sink Pin 1 Blue Relay NC Pin 2 Purple Relay armature ...

Страница 2: ... and affix bag to top of mounting base adhesive side down 8200 0184 10 Rev C Page 2 of 12 IMPORTANT Power the dome heater fans turn on and check it performs its homing routine During this routine the camera lens moves up into the dome housing down to the floor pans slowly and moves up to its home position The controller can then be used to call up and control the dome If OK continue If not see Tro...

Страница 3: ... been pulled to the installation site To install the outdoor mounting structure see documents shipped with the structure About the Product The outdoor housing has a sunshield cover and bubble that protect the SpeedDome Ultra dome camera Tamperproof screws affix the bubble to the housing The housing is temperature controlled and weatherproof A built in thermostat and heater prevent ice from forming...

Страница 4: ...if inher ently limited with 8 amps maximum output current and a maximum of 100VA available or if not inherently limited fused with a maximum value of 3 3 Amps meeting section 2 11 of IEC950 and a maximum of 250VA available The power supply can be obtained through American Dynamics or through another source where the provider can furnish the verification This is required to assure electrical safety...

Страница 5: ...s the gasket seal between the bubble and the housing Plugged drain holes in the bubble trim ring Cracked bubble Tamperproof screws that are missing or improperly tightened compromise the gasket seal between the bubble and the housing Ensure lanyard is not caught between a flange and trim ring gasket and b trim ring and sunshield Parts List for Authorized Users The parts listed below and shown in t...

Страница 6: ...munication protocols and cable networks see Communication Protocols and Cable Networks 8000 2573 19 Data cable requirements SensorNet RS 422 Manchester Cable type 1 unshielded twisted pair 2 shielded twisted pair 1 shielded twisted pair Wire gauge 22 AWG 22 AWG 18 AWG Connection Non polarized Polarized Polarized Max devices on line 32 10 3 Power data and video cables can be ordered separately or w...

Страница 7: ...fer to controller matrix switcher instructions for information about controlling outputs auxiliaries Command Priority If both commands to control the heaters are issued in sequence the first command runs to completion 3 hours 23 minutes then the second command runs For example the command to run the heaters on continuous high mode is issued Output Auxiliary 4 On Five minutes later the command to r...

Страница 8: ...al housing to discharge it before touching the board 1 As shown above detach the circuit board from the housing by A Pushing fingers molded into the base away from the board while B Pulling on the dust cover protecting the board s spring finger connector Note Keep the dust cover in place for the next two steps 2 On the top side of the circuit board place jumper E1 across pins 1 2 for unterminated ...

Страница 9: ...N A 24Vac CAUTION Use a 2 5mm 0 1in slotted screwdriver Using a blade too wide can damage connectors CAUTION Screws on the ac connector are delicate DO NOT over tighten them 3 Verify data is reaching the housing SENSORNET or RS 422 Press and hold switch SW2 on the environmental PC board and observe the yellow comm LED The LED should blink SensorNet or glow steadily RS 422 To verify RS 422 connecti...

Страница 10: ...ch as a picture on the video monitor or dome movement 2 Detach the dome camera to access the environmental PC board Note Power to fans comes from the dome Fans will not function with the dome removed CAUTION Touch the metal housing before handling the environmental PC board 3 Verify power is reaching the housing Press and hold switch SW2 and observe the green ac power LED it should glow steadily I...

Страница 11: ...ing the two screws NO Plug the connector in reinstall the environmental PC board and reattach the dome If the fans still do not work replace the fan heater assembly Specifications Electrical combined dome and housing Input Voltage 24 to 30Vac 50 60 Hz UL Listed Class 2 Certified Limited Power Source Design Tolerance 20 to 36Vac 50 60 Hz Power Consumption 80W max Power On In Rush current 3A Surge P...

Страница 12: ...mpowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any par...

Отзывы: