INSTALLATION INSTRUCTIONS

AD32 ENHANCED T

OUCH 

T

RACKER

W/VMS

8000-2671-02, REV. A

Figure 3.  VMS Wiring Diagram—Remote Switcher Location

5 2 3

RJ45

RJ45

RJ45

DB9 (M)

24 Vac A

Ground

24 Vac B

1

2

3

4

5

8

7

6

1

2

3

4

5

8

7

6

5 4 2

RJ45

RJ45

J1

J2

J3

EIM

5    4    3    2    1

1           3         5           7         9       11       13       15       17       19       21       23      25       27       29       31

2         4         6        8        10       12       14       16       18       20      22       24       26       28       31       32

1   2  3   4   5   6   7   8             SI      NO NC C

1           2            3          4            5

1             2             3

RS232 PORTS

MONITORS

ALARMS

RELAY

120V
60Hz

CAMERAS

Transforme

J3 Wiring

Pin

Function

1

N/A

2

24Vac A

3

Ground

4

24Vac B

5

N/A

DB9 (M) Wiring

Color

Pin

Function

Green

3

Receive

Red

2

Transmit

Orange

5

Ground

Touch Tracker

RJ45 Wiring

Color

Pin

Green

5

Red

4

Orange

2

Video Matrix Switcher

3-wire, 18AWG
shielded cable

Shield

EIM

Terminal

Box

Data
Cable

Modular
Cable

Modular
Cable

Ferrite
Core

Remote
Terminal
Box

Содержание ADTT32E

Страница 1: ...mber 0351 0474 07 INSTL KIT TOUCH TRKR W RJ45 1 Description Qty Part No CABLE ASSY MDLR 14FT 8 COND CROSS P 1 6003 0047 01 SCR THD CUT M2 9X9 5 PHP ST Z T1 1 5899 0004 102 ANCHOR PLASTIC W O SCREW 8 1...

Страница 2: ...ary TOUCH TRACKER Secondary TOUCH TRACKER Video Matrix Switcher EIM DB9 M COLOR PIN FUNCTION Green 3 Receive Red 2 Transmit Orange 5 Ground NOTE View Manager 32 supports up to 2 controllers Terminate...

Страница 3: ...oot to the Camera Control Mode Figure 2 Ferrite Core Attachment 0 in 2 54 3 81 cm 1 1 5 Resetting a Dome 1 Use the number buttons to select the dome to reset then press the Camera button 2 Press Menu...

Страница 4: ...the number buttons to select a dome to test then press the Camera button 2 Press Menu 3 Using the Tracker Ball scroll down to Ping Dome TTR 4 Press the zoom top line or focus bottom line button to sel...

Страница 5: ...s to one end of the 3 conductor cable then attach the lugs to the EIM power transformer 6 Connect the power transformer cable and the SensorNet data cable and if required the data cable to EIM 2 to th...

Страница 6: ...2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32 1 2 3 4 5 6 7 8 SI NO NC C 1 2 3 4 5 1 2 3 RS232 PORTS MONITORS ALARMS RELAY 120V 60Hz CAMERAS Transforme J3 Wiring Pin Function 1 N A 2 24Vac A 3 Ground 4...

Страница 7: ...on 1 Ground 2 Alarm 1 3 Alarm 2 4 Alarm 3 5 Alarm 4 6 Alarm 5 7 Alarm 6 8 Alarm 7 9 Alarm 8 10 Ground 11 External Sync Ground 12 External Sync Input 13 Ground 14 Relay Normally Open 15 Relay Normally...