![American Dynamics ADTT32E Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/american-dynamics/adtt32e/adtt32e_installation-instructions-manual_2923729002.webp)
INSTALLATION INSTRUCTIONS
AD32 ENHANCED T
OUCH
T
RACKER
W/VMS
8000-2671-02, REV. A
2
Figure 1. VM32 Wiring Diagram
2 1
3
5 4
J-Box #1
EIM #1
DB9 (M)
RJ45
RJ45
P1
P2
P3
P4
P5
P6
P8
RJ45
RJ45
EIM #2
J1
J2
J3
E1
3 2 1
1-2 TERMINATED
2-3 UNTERMINATED
J1
J2
J3
E1
3 2 1
1-2 TERMIN AT ED
2-3 UNT ERMINA TED
5 2 3
2 1
3
5 4
P1
P2
P3
P4
P5
P6
P8
2 1
3
5 4
2 1
3
5 4
J-Box #2
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
2 4 6 8 10 12 14 16 18 20 22 24 26 28 31 32
1 2 3 4 5 6 7 8 SI NO NC C
1 2 3 4 5
1 2 3
RS232 PORTS
MONITORS
ALARMS
RELAY
120V
60Hz
CAMERAS
RJ45
5 4 2
ASSY
0301-0340-01 REV-
ASSY
0301-0340-01 REV-
UniCard
P3
UniCard
P3
3 2 1
DB9 (M)
5 2 3
RJ45
5 4 2
3 2 1
Primary
T
OUCH
T
RACKER
Secondary
T
OUCH
T
RACKER
Video Matrix Switcher
EIM DB9 (M)
COLOR
PIN FUNCTION
Green
3
Receive
Red
2
Transmit
Orange
5
Ground
NOTE:
View Manager 32 supports up
to 2 controllers. Terminate E1
on the EIM that is on an end
point of the SensorNet network.
NOTE:
The maximum combined SensorNet
cable length is 1219m (4000').
24 Vac B
Ground
UNTERMINATED
EIM Transformers
24 Vac A
24 Vac B
Ground
24 Vac A
RJ45 Wiring
COLOR
PIN
Green
5
Red
4
Orange
2
J-Box P8
COLOR
PIN Function
Orange
1
Host A
Yellow
2
Host B
Orange
3
Auxillary A
Yellow
4
Auxillary B
J-Box P1-P6
COLOR PI
N
Function
Orange
1
SensorNet A
White
2
28Vac
Red
3
Ground
Black
4
28Vac
Yellow
5
SensorNet B
UniCard P3 Wiring
COLOR
PIN FUNCTION
Orange
1
SensorNet A
Yellow
2
SensorNet B
Black
3
24Vac A
Red
4
Ground
White
5
24Vac B
TERMINATED
Ferrite Core
Ferrite Core
Modular
Cable
Data Cable