Defining Automatic System Functions
3-15
Alarm Programming Overview
You can define up to 136 different alarms (128 from dome inputs, 8 from
switcher inputs) for your system. An
alarm
is triggered when one of the
inputs connected to a dome or the switcher changes from its normal state to
its abnormal state. For example, if the input is a smoke detector, its normal
state would be “not detecting smoke.” However, when smoke is detected, it
changes to its abnormal state, and this triggers an alarm. Refer to the Dome
Configuration Worksheet in Appendix A to determine the normal and
abnormal state for each input.
When an alarm is triggered, it can automatically call up one video action
(either a Quick View, a Pattern, or a fixed shot) and initiate one output. This
video action must have been defined for the same dome that the output is
connected to, and vice versa. Refer to the Dome Configuration Worksheet in
Appendix A to determine which outputs are connected to which domes. In
addition, use this worksheet to determine which Quick Views and Patterns
were defined for which domes.
When the T
OUCH
T
RACKER
is in the menu/programming mode, the Tracker
Ball enables you to move the cursor around on the LCD. The blinking square
on the LCD indicates the cursor's location. Move the Tracker Ball left and
right to move the cursor among the fields on the LCD. A setup alarm LCD
contains the following information:
CAM01/1==> MON 5
CAM 09 VIEW96
1
2
3
4
5
This is the currently selected
dome. Use Previous and Next
to cycle between the cameras
and the Switcher (Cam 33).
This is the specific dome input
that will trigger an alarm when
it senses a change in state.
This is the monitor where the
Quick View, Pattern, or fixed shot
will be shown when the alarm is
triggered.
This is the dome whose video
appears on the selected
monitor, and whose output will
be initiated when the alarm is
triggered.
This is the Quick View or
Pattern that appears when the
alarm is triggered. If no
number appears, this is a