SETUP
AD1684B
SETUP
Receiver Configuration Setup
AD1684B Receivers may be configured as a two-channel
Pan/Tilt and Lens control unit or a single channel unit with
four auxiliaries. A two-position Berg jumper, labeled J5 (see
Figure 1), is provided to establish this configuration.
The Receiver is factory set for two-channel operation. The
output configuration can be changed to single-channel with
four auxiliaries by moving the jumper from the “NO AUX”
position to the “AUX” position. In this position, Channel B
(J6 and J3 connectors) is for auxiliary functions only.
2
J7
J4
J1
J6
J3
CODE
POWER
CAM/AUX
CHANNEL
A
CHANNEL
B
G
N
D
N
E
U
T
R
A
L
H
O
T
F1
F2
S1
S2
6
1
6
1
CAMERA I.D.
CHANNEL
A B
CA BLE INPUT HOLES
J9
J5
R4
BLACK
WHITE
SHIELD
Figure 1 - AD1684B Connector and Switch Location
CAUTION - Due to the presence of non-
insulated components with hazardous
voltages, the following internal adjustments
should be performed by qualified service
personnel only.
!