12
C. DRYER ENCLOSURE REQUIREMENTS
Even though a 30-inch clearance is acceptable, it is recommended that the rear of the dryer be positioned
approximately two (3) feet (36-inches) from nearest obstruction (i.e. wall) for ease of installation, maintenance
and service. Bulkheads and partitions
should be
made from noncombustible materials. The clearance between
the bulkhead header and the dryer
must be
a minimum of 4 inches and must not extend more than 4 inches to the
rear of the dryer front. The bulkhead facing must not be closed in all the way to the top of the dryer. A 2-inch
clearance is required.
NOTE
: Bulkhead facing
should not be
installed until after dryer is in place. Ceiling area
must be
located a
minimum of 12 inches above the top of the dryer.
NOTE
: When fire sprinkler systems are located above the dryers, a minimum of 18-inches above the dryer
console (module) is suggested. Dryers may be positioned side wall to side wall however, 1 or 2
inches is suggested between dryers (or wall) for ease of installation and maintenance. Allowances
must be
made for the opening and closing of the control and lint doors.