2. Electrical Service Specifications
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 240 VAC, the supply voltage must match the electric service specifications of
the data label
exactly
.
IMPORTANT:
The wire size
must be
properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE
NOT
THE
SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
MLG-78II (Gas)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 240 VAC
ARE NOT THE SAME. When ordering,
specify
exact voltage
.
When fuses are used they
must be
dual element, time delay, current limiting, class RK1 or RK5
ONLY
.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY
. For others, calculate/
verify correct breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers
must be
3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz
50 Hz
120
1Ø
2
13
---
*
20
20
208
1Ø
2
7.6
---
*
12
15
208
3Ø
3/4
4.7
---
*
8
15
240
1Ø
2
7
---
*
10
15
240
3Ø
3
4.9
5.5
*
8
15
380-400
3Ø
3/4
---
3
*
5
15
416
3Ø
3/4
---
3.1
*
5
15
460/480
3Ø
3/4
2.8
---
*
5
15
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.