OM
ADG-230D (Gas)
ADG-235ED (Gas)
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT
: 208 VAC
AND
230/240 VAC
ARE NOT THE SAME
.
When ordering
, specify exact voltage.
NOTE
:
A. Circuit breakers are thermal magnetic (industrial) type
ONLY
. For others, calculate/verify correct breaker size
according to appliance amp draw rating and type of breaker used.
B. Circuit breakers for 3-phase (3ø) dryers
must be
3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
(60 Hz)
MINIMUM
WIRE SIZE*
CIRCUIT
BREAKER
120
1ø
2
9.6
14
20
208
1ø
2
5.8
14
15
230/240
1ø
2
5.3
14
15
208
3ø
3
2.9
14
15
230/240
3ø
3
3.2
14
15
* AWG Stranded Type Wire...for individual lengths less than 100 feet (30.48m).
NOTE:
Contact factory for electrical information not listed.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice
or obligation.