AD-235D/AD-235ED

Installation Manual

ADC

 Part No. 113118

For replacement parts, contact the reseller from which the dryer

was purchased or

American Dryer Corporation

88 Currant Road

Fall River MA 02720-4781

Telephone: (508) 678-9000  /  Fax: (508) 678-9447

e-mail: [email protected]

110199JEV/tcosta

WARNING:  For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.

Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.

WHAT DO YOU DO IF YOU SMELL GAS

* Do not try to light any appliance.
* Do not touch any electrical switch; do not use

any phone in your building.

* Clear the room, building or area of all

occupants.

* Immediately call your gas supplier from a

neighbor's phone.  Follow the gas supplier's
instructions.

* If you cannot reach your gas supplier, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

AVERTISSEMENT:  Assurez-vous de bien
suivre les instructions données  dans cette
notice pour réduire au minimum  le risque
d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.

Ne pas entreposer  ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage  de cet appareil ou de tout autre
appareil.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:

* Ne pas tenter  d’allumer  d’appareil.
* Ne touchez à aucun interrupteur.  Ne pas

vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez..

* Évacuez la pièce, le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de

gaz depuis un voisin.  Suivez les instructions
du fournisseur.

* Si vous ne pouvez rejoindre le fournisseur

de gaz, appelez  le  service des incendies.

L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.

Содержание AD-235D

Страница 1: ...you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier AVERTISSEMENT Assurez vous de bien su...

Страница 2: ...out autre appareil We have tried to make this manual as complete as possible and hope you will find it useful ADC reserves the right to make changes from time to time without notice or obligation in p...

Страница 3: ...D IF NEAR DRYER S IN OPERATION DRYER S SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION CAUTION FOR YOUR SAFETY DO NOT DRY MOP HEADS IN THE DRYER DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUM...

Страница 4: ...ANT PLEASE OBSERVE ALLSAFETY PRECAUTIONS displayed on the equipment and or specified in the installation manual included with the dryer The wiring diagram for the dryer is located in the front electri...

Страница 5: ...PPLY 11 E EXHAUST REQUIREMENTS 13 F ELECTRICAL INFORMATION 17 G GAS INFORMATION 21 H PREPARATION FOR OPERATION 25 I PREOPERATIONAL TESTS 25 J SHUT DOWN INSTRUCTIONS 27 SECTION IV OPERATING INSTRUCTION...

Страница 6: ...ROUBLESHOOTING 36 SECTION IX DATA LABEL LOCATION INFORMATION 42 A Data Label 42 SECTION X PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 44 SECTION XI BURNER TUMBLER HI LIMIT MANUAL RESET IN...

Страница 7: ...he number received and the number refused must be noted on the receipt 4 If you determine that the dryer was damaged after the trucker has left your location you should call the delivering carrier s f...

Страница 8: ...ch c DO NOT use any phone in your building d Clear the room building or area of ALL occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions f If y...

Страница 9: ...TEST EDITION NOTE Failure to do so will VOID THE WARRANTY 9 UNDER NO CIRCUMSTANCES should the dryer door switch lint door switch or heat safety circuit ever be disabled WARNING PERSONAL INJURY or FIRE...

Страница 10: ...Hz 208 240v 3 60 50 Hz APPROX WEIGHT UNCRATED 850 lbs 385 6 kg APPROX WEIGHT CRATED 900 lbs 408 2 kg HEAT INPUT 144 000 btu hr 36 288 kcal hr AIRFLOW 800 cfm 22 65 cmm INLET PIPE SIZE 3 4 N P T EXHAUS...

Страница 11: ...T ADG 235D Gas NOTE ADC reserves the right to make changes in specifications at any time without notice or obligation...

Страница 12: ...U ADG 235ED Gas NOTE ADC reserves the right to make changes in specifications at any time without notice or obligation...

Страница 13: ...inal location while still attached to the skid or with the skid removed To unskid the dryer locate and remove the four 4 bolts securing the base of the dryer to the wooden skid Two 2 are at the rear o...

Страница 14: ...tioned approximately 2 feet 0 61 meters away from the nearest obstruction i e wall for ease of installation maintenance and service Refer to the illustration below 6 provisions must be made for adequa...

Страница 15: ...tails NOTE Air considerations are important for proper and efficient operation D FRESH AIR SUPPLY Air supply make up air must be given careful consideration to assure proper performance of each dryer...

Страница 16: ...ted near duct work exhaust outlets If make up air opening s are too close to the exhaust outlet lint and fumes may be drawn back into the dryer area through these openings NOTE Component failure due t...

Страница 17: ...with as few turns as possible It is suggested that the use of 90 turns in ducting be avoided use 30 or 45 angles instead The shape of the exhaust duct work is not critical so long as the minimum cros...

Страница 18: ...zontal duct work from the weather a 90 elbow bent downward should be installed where the exhaust exits the building If the exhaust duct work travels vertically up through the roof it should be protect...

Страница 19: ...eet 6 1 meters with two 2 elbows When the duct work approaches the maximum limits as noted in this manual a professional heating venting air conditioning HVAC firm should be consulted for proper venti...

Страница 20: ...NS IMPORTANT DO NOT use screens or caps on the outside opening of the exhaust duct work...

Страница 21: ...sult in personal injury or component failure NOTE Component failure due to improper installation will VOID THE WARRANTY A separate circuit servicing each dryer must be provided The dryer must be conne...

Страница 22: ...d connection of the dryer to a grounded cold water pipe DO NOT ground to a gas pipe or hot water pipe The grounded cold water pipe must have metal to metal connection ALL the way to electrical ground...

Страница 23: ...e dryer No single phase 1 input connection is required on a 3 phase 3 dryer a 3 Phase 3 Hookup For gas dryers manufactured for operation at 3 phase 3 the electrical connections are made at the power d...

Страница 24: ...ing and type of breaker used B Circuit breakers for 3 phase 3 dryers must be 3 pole type SERVICE VOLTAGE PHASE WIRE SERVICE APPROX AMP DRAW 60 Hz MINIMUM WIRE SIZE CIRCUIT BREAKER 120 1 2 9 6 14 20 20...

Страница 25: ...rom supply as noted can cause irreparable damage to the gas valve VOIDING THE WARRANTY WARNING FIRE or EXPLOSION COULD RESULT 1 Gas Supply The gas dryer installation must meet the American National St...

Страница 26: ...10 5 inches water column 26 1 mb There is no regulator or regulation provided in a L P dryer The water column pressure must be regulated at the source L P tank or an external regulator must be added...

Страница 27: ...operated appliances on the supply line etc Specific information regarding supply line size should be determined by the gas supplier NOTE Undersized gas supply piping can create a low or inconsistent p...

Страница 28: ...supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa NOTE The dryer must be isolated from the gas supply piping system by closing its individ...

Страница 29: ...t it is closed and secured in place 9 Rotate the basket tumbler by hand to be sure it moves freely I PREOPERATIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory Howe...

Страница 30: ...is filled with air so it may take a few minutes for the air to be purged from the lines NOTE During the purging period check to be sure that ALL gas shutoff valves are open NOTE Gas dryers are equipp...

Страница 31: ...with the most commonly used program parameter selections If microprocessor controller computer program changes are required refer to the computer programming manual which was shipped with the dryer 7...

Страница 32: ...g key 3 The dryer will now start and the L E D display will read the setting and the time vended i e LO 10 4 The cycle time will count down until the drying and cooling cycles are completed 5 Upon com...

Страница 33: ...selection is made 2 Selection setting changes can be made at any time during the drying cycle by opening and closing the main door and then making a new selection 3 Additional time can be purchased a...

Страница 34: ...so that your inquiry is handled in an expeditious manner B PARTS 1 Replacement parts should be purchased from the reseller from whom the ADC equipment was purchased If the reseller cannot be contacted...

Страница 35: ...ADC commercial warranty covering your particular dryer s contact the ADC reseller from whom you purchased the equipment and request a dryer warranty form If the reseller cannot be contacted or is unkn...

Страница 36: ...ge 4 ALL returns must be properly packaged to insure that they are not damaged in transit Damage claims are the responsibility of the shipper IMPORTANT No replacements credits or refunds will be issue...

Страница 37: ...years of efficient trouble free and most importantly safe operation WARNING LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE THE ACCUMULATION OF LINT CAN CREATE A POTENTIAL FIRE HAZARD WARNING KEEP DRYER...

Страница 38: ...lint accumulation in customer furnished exhaust duct work system and from the dryer s internal exhaust ducting WARNING THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN CREATE A POTENTIAL FIRE HA...

Страница 39: ...heck of ALL safety devices door switches lint compartment switches sail switches burner and hi limit thermostats C LUBRICATION The motor bearings idler bearings and under normal most conditions the tu...

Страница 40: ...re being returned to the factory The information provided should not be misconstrued as a handbook for use by an untrained person making repairs IMPORTANT When replacing blown fuses the replacement mu...

Страница 41: ...ttent connection in main door circuit F Microprocessor controller computer L E D display reads dSFL 1 L E D display consistently reads dSFL and will not clear a Microprocessor controller computer 1 8...

Страница 42: ...somewhere in the basket tumbler rotation detection circuit or the microprocessor controller computer program related to this circuit PL01 is set incorrectly in the active mode SEn where the dryer is...

Страница 43: ...m J4 above a If the dryer is not equipped with optional battery backup 1 Loose connection somewhere in the power source to the dryer 2 Loose connection in main power circuit to the microprocessor cont...

Страница 44: ...ring connections to the assembly 3 No gas check shutoff valves or insufficient low water column W C pressure gas supply 4 Failed DSI module 5 Failed gas valve O No heat ignitor sparks burner goes on a...

Страница 45: ...ork R Dryer is making scraping noise at basket tumbler wrapper area 1 Check for object s caught in the basket tumbler wrapper area 2 Basket tumbler is out of proper alignment a Check both the vertical...

Страница 46: ...from ADC This information is on the data label that is located in the left inside front side panel as shown in the illustration above When contacting ADC please have the model number as well as the se...

Страница 47: ...ur particular model 4 TYPE OF HEAT This describes the type heat for your particular dryer gas either natural gas or liquid propane L P or steam 5 HEAT INPUT for GAS DRYERS This describes the heat inpu...

Страница 48: ...mputer board reestablish power to the dryer b Start the drying cycle c Verify that the motors and the heat indicator dots in the microprocessor controller computer light emitting diode L E D display a...

Страница 49: ...cycle When the gas burner ignites within the chosen trial for ignition time 6 seconds the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open as long as there i...

Страница 50: ...The burner flame should now be established e With the burner flame on remove the flame sensor wire from the FS terminal of the DSI module f The burner flame must shut off and the ignition module must...

Страница 51: ...ostat and will start or continue through the drying cycle with no heat The applicable open tripped manual reset hi limit must be reset manually This hi temperature condition may be caused due to a res...

Страница 52: ...ADC 113118 1 11 11 99 50 2 11 29 99 200 3 01 03 00 500 4 08 04 00 500 5 09 11 00 25...