sound activation.

Assigning DMX Address: 

Each dipswitch has a preset value. A spe-

cific DMX address is set by combining the dipswitches that sum your 
desired value. For example: To achieve a DMX address of 7, combine 
dipswitches 1, 2, and 3. Since dipswitch 1 has a value of 1, dipswitch 
2 has a value of 2, and dipswitch 3 has a value of 4, the combination 
of the three create a DMX value of 7. (See example below).

Set DMX address 1:         

Set DMX address 7:

Dip-switches #   1 = 1            

 

Dip-switches #   1 = 1

 

 

 

 

 

 

             2 = 2

 

 

 

 

             

             3 = 4

 

 

 

 

             

       

   = 7

   

 

      

 

 

 

 

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Tri Fecta™ can be controlled via DMX-512 protocol. 

The Tri Fecta™ is a three channel DMX unit. The DMX address is set 
on the side panel of the Tri Fecta.™ Your unit and your DMX controller 
require a standard 3-pin XLR connector for data input and data output 
(Figure 1). If you are making your own cables, be sure to use standard 
two conductor shielded cable (This cable may be purchased at almost 
all pro sound and lighting stores). Your cables should be made with 
a  male  and  female  XLR  connector  on  either  end  of  the  cable.  Also 
remember that DMX cable must be daisy chained and can not be split.

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

  Tri Fecta™  

 

 

 

                       Set Up

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR socket of the last unit 
in your daisy chain to terminate the line. Using a cable terminator (ADJ 
part number Z-DMX/T) will decrease the possibilities of erratic behav-
ior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  Tri Fecta™  

 

 

 

                       Set Up

Содержание Tri Fecta

Страница 1: ...n found or parts are miss ing please contact our toll free customer support number for further instructions Please do not return the unit to your dealer without first contacting customer support Custo...

Страница 2: ...mpt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main po...

Страница 3: ...it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first readi...

Страница 4: ...f a internal short or power surge 3 Power Cord Connect only to a matching power outlet Never usethis fixture is the ground prong has been removed or broken off 4 Microphone This microphone receives ex...

Страница 5: ...lex This is a universal pro tocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fixture DMX data...

Страница 6: ...duces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixtu...

Страница 7: ...units and they will react the same as the MASTER 4 Use the sensitivity knob on the rear of the master unit to make it more or less sensative to sound 5 The optional MINI C Controller may be used to c...

Страница 8: ...45 47 48 50 99 101 96 98 93 95 87 89 90 92 84 86 66 68 78 80 81 83 75 77 69 71 72 74 57 59 63 65 60 62 54 56 51 53 102 104 105 107 108 110 FIG 1 Channel Value Function 1 COLORS 0 63 LASER OFF 64 127...

Страница 9: ...ecta DMX Traits FIG 2 Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external lenses should be carried out periodically to optimize light output 1 Use normal glass cleane...

Страница 10: ...as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above American DJ Inc w...

Отзывы: