background image

©

American DJ

®

 - www.americandj.com - Emerald Sky™ Instruction Manual Page 4

©

American DJ

®

 - www.americandj.com -  Emerald Sky™ Instruction Manual Page 3

Please carefully read and understand the instructions in this manual 
thoroughly before attempting to operate this unit. These instructions 
contain  important  safety  information  regarding  the  use  and  mainte-
nance  of  this  unit.  Please  keep  this  manual  with  the  unit,  for  future 
reference. 

CAUTION IMPORTANT! When installing this projector, make sure 
that  it  is  mounted  in  a  manner  that  prevents  the  audience  from 
looking  directly  into  the  beam,  and  the  beam  from  striking  the 
audience.

•  4.9mW Green Laser Diode
•  Dual Laser Output
•  Sound Active and Auto Mode 
•  DMX-512 Protocol Compatible (Uses Two DMX Channels)
•  Stand Alone and Master/Slave Operation 
•  Volume Sensitivity Knob

Safety  Issues: 

This  unit  may  blow  the  fuse  if  the  maximum  allotted 

load of 2 amps is reached.

•  To reduce the risk of electrical shock or fire, do not expose this unit

     rain or moisture.
•   Do not spill water or other liquids  into or on to your unit.
•   Do not attempt to remove or break off the ground prong from the
    electrical cord. This prong is used to reduce the risk of electrical  

   shock and fire in case of an internal short. Do not attempt to oper-

   ate this unit if the power cord has been frayed or broken.
•   Disconnect from main power before making any type of connection.
•   Do not remove the cover under any conditions. There are no user  
   serviceable parts inside.
•   Always be sure to mount this unit in an area that will allow proper  
   ventilation. Allow about 6” (15cm) between this device and a wall.
•   Do not attempt to operate this unit, if it becomes damaged.
•   This unit is intended for indoor use only, use of this product out-
   doors voids all warranties.
•   During long periods of non-use, disconnect the unit’s main power.
•   Always mount this unit in safe and stable matter.
•   Power cords should be routed so they are not likely to be walked  
   on, pinched by items placed upon or against them.
• Cleaning -The fixture should be cleaned only as recommended by  
   the manufacturer. See page 6 for cleaning details.
•   Heat -The appliance should be situated away from heat sources  
   such as radiators, heat registers, stoves, or other appliances    
   (including amplifiers) that produce heat.
•   The fixture should be serviced by qualified service personnel when:
    A.  The power-supply cord or the plug has been damaged.
    B.   Objects have fallen on, or liquid has been spilled into the unit.
    C.  The unit has been exposed to rain or water.
    D.   The unit does not appear to operate normally or exhibits a
            marked change in performance.

!

!

 Emerald Sky™    

 

         Warranty Registration

 Emerald Sky™    

 

 

           

Features

 Emerald Sky™    

 

 

 General Instructions

 Emerald Sky™    

 

 

    Safety Precautions

The  Emerald  Sky™  carries  a  90  day  limited  warranty.  Please  fill  out 
the  enclosed  warranty  card  to  validate  your  purchase.  All  returned 
service items whether under warranty or not, must be freight pre-paid 
and accompany a return authorization (R.A.) number. The R.A. num-
ber  must  be  clearly  written  on  the  outside  of  the  return  package.  A 
brief description of the problem as well as the R.A. number must also 
be written down on a piece of paper included in the shipping carton. 
If the unit is under warranty, you must provide a copy of your proof of 
purchase  invoice.  You  may  obtain  a  R.A.  number  by  contacting  our 
customer support team on our toll free customer support number. All 
packages  returned  to  the  service  department  not  displaying  a  R.A. 
number on the outside of the package will be returned to the shipper.

Содержание Emerald Sky

Страница 1: ...e sound active unit or in a Master Slave configuration The unit can also be controlled via DMX controller The unit s sound sensitivity may be adjusted by a sensitivity knob on the rear of the unit For...

Страница 2: ...d This unit is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable...

Страница 3: ...it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first read...

Страница 4: ...low frequency sounds only tapping on the microphone and high pitch sounds may not trigger the unit 3 XLR Input Jack This male input jack is used to accept an incom ing DMX signal or Master Slave sign...

Страница 5: ...voltage for your American DJ Emerald Sky The American DJ Emerald Sky is 120v only Because line voltage may vary from venue to venue you should be sure your unit voltages matches the wall outlet voltag...

Страница 6: ...reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fi...

Страница 7: ...last fixture 3 Assign a DMX address to the unit by following DMX setup on pages 10 12 American DJ www americandj com Emerald Sky Instruction Manual Page 13 American DJ www americandj com Emerald Sky I...

Страница 8: ...function as the Master and set dipswitch 11 to the ON position This unit must be the first unit in line 5 Turn dipswitch 1 to the ON position on the SLAVE units and they will react the same as the MAS...

Страница 9: ...sole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the sole discretion of American DJ All products cov...

Страница 10: ...improvements in the design of this unit and this manual are subject to change without any prior written notice Emerald Sky Specifications American DJ American DJ World Headquarters 6122 S Eastern Ave...

Отзывы: