UNITED KINGDOM CORDS ONLY
WARNING
THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wire of this mains lead are colored in
accordance with the following code:
BLUE
— NEUTRAL
BROWN
— LIVE
YELLOW/GREEN
— EARTH
As the colors of the wires in the mains lead of this
appliance may not correspond with the colored
markings identifying the terminals in your plug
proceed as follows: The wire colored brown must
be connected to the terminal marked with the letter
–L– or colored red.
The wire colored blue must be connected to the
terminal marked with the letter –N– or colored
black.
The wire colored yellow/green must be connected
to the terminal marked with the letter E or
Ensure that your machine is connected correctly. If
you are in any doubt consult a qualified electrician.
This appliance must be protected by a 13A fuse if
a 13A (B.S. 1363) plug is used or, if any other
type of plug is used, by a 5A fuse either in the
plug or adapter or at the distribution board.
AMERIC AXIAL FAN TROUBLE SHOOTING
CAUTION: All service procedures should be executed with the unit
unplugged.
PROBLEM
CAUSE
SOLUTION
Unit will not run.
Unit runs but fan
makes loud scraping
noise.
Unit runs but vibrates
excessively.
Unit runs but fan does
not turn.
Unit runs briefly, then
shuts off on overload.
1. No power to unit.
2. Switch not on.
3. Switch is faulty.
4. Faulty/broken cord or motor wire.
1. Unit has been severely jolted causing
fan to rub against housing.
2. Unit has been severely jolted causing
housing to deform.
1. Severe jolt has bent motor shaft
causing unit to be out of balance.
2. Fan blade damaged.
3. Dirt build up on one side of fan blade.
1. Fan is jammed against housing.
2. Capacitor wire has broken/come
loose, capacitor has failed.
3. Housing has been damaged such that
it presses on the fan blade.
1. Motorbearings are failing, or motor has
developed an internal electric fault.
2. Intake grill and/or exhaust grill is
obstructed.
3. Excessive duct length.
1. Plug unit in. Check circuit breaker.
2. Place in “ON” position.
3. Replace switch.
4. Perform continuity check, using
volt/amp meter. Repair/replace
faulty/broken wire.
1.Remove motor and replace damaged
motor mounts.
2. Replace housing/unit as necessary.
1. Remove and replace motor. Replace
fan blade if necessary.
2. Replace fan blade.
3. Clean fan blade.
1. Remove motor and replace damaged
motor mounts. Replace fan blade if
necessary.
2. Repair/replace wires/capacitor as
necessary.
3. Replace housing/unit as necessary.
1. Replace motor.
2. Remove obstruction.
3. Reduce duct length to recommended
maximum.
785 Bonnie Lane
Elk Grove Village, IL 60007
Tel: (847) 364-4646 • (800) 364-4642
Fax: (847) 364-4695
Email: [email protected]
www.americ.com
U.K. BS#
‘BS 3456 Approved’
Item
Part#
Each Description
1
03-00566
1
#6-3/8 SS Phil Pan HD Screw
2
04-00007
1
Switch Plate Assy 115V
(capacitor includer)
04-00800
1
Switch Plate Assy 230V
(capacitor includer)
04-00807
1
Switch Plate Assy 12V DC
04-00078
1
Capacitor 115V
04-00079
1
Capacitor 230V
04-00200
1
Cord 115V
04-00201
1
Cord 230V
04-00202
1
Cord 12V DC
3
04-00026
1
Shell Housing-Chrome Yellow
02-01017A
1
Grommet, Rubber #896
4
03-01040
1
Bolt, SS M3 x .5 x 20mm HH MS
5
03-01172
1
Washer, #6 SS
6
13-00964A
1
Foot, Rubber 5/16 x .625 Blk
7
03-00979A
1
Well Nut, M3 x .5 E632
8
03-00015
1
Nut, Nyloc 8-32 ZP
9
03-00052
1
Spacer 3.75 x .171 x .125 Nylon
10
04-00013
1
Grill
11
03-00016
1
Screw, 8-32 x 1.125 PHP ZP
12
03-00013
1
Washer-3/16 Rivet ZP
13
03-00030
1
3/16 Alum Rivet Anodized
14
02-00027
1
Motor Assy, 115V
02-00327
1
Motor Assy, 230V
02-00627
1
Motor Assy, 12V DC
03-00019
1
Clip “C” Retainer
04-00018
1
Fan Blade, 10'' Axial Plastic
03-00021
1
Spring Pin
1
Vane Motor Mount (115V)
15
04-00016
1
Duct Ring 8''
(Refer to item # on pictorial breakdown)
Содержание VAF-1500
Страница 7: ...VAF 1500 PICTORIAL BREAKDOWN ...