PURE 2.0 OPERATING INSTRUCTIONS
08/21/19
4211-1430
Page 4 of 4
Mounting the Control
Install the PURE 2.0 control inside or outside the steam room using the control cable previously
installed If mounting to a smooth, flat wall, the adhesive pad provided will work well to mount the
control and seal the cable hole.
The adhesive will stick to the wall quickly so be sure to accurately
place
and level the control before attaching it to the wall!
If the surface is uneven or has grout lines, we recommend using a small amount of silicone
to mount the PURE 2.0 control. If using silicone, run a bead around the control’s cable end
and another bead around the back of the control as shown here. Then tape in place
on the wall until the silicone has set up.
Connect the cable to the control’s cable end, slide the cable
into the wall, and mount the control.
Be sure to carefully level the control while mounting!
Troubleshooting
The PURE 2.0 has error displays to assist with troubleshooting. If an error should occur in the steamer or other
equipment (PURE 2.0 control, temperature sensor, etc.) an error message will be shown using LED indicators.
The indicator LEDs will flash while one LED on the 1-10 scale is continuously lit or flashing. The lit 1-10 LED
indicates the error: steady = #1 -10, flashing indicates #11-20.
Some errors are not applicable to steam and are
not listed here.
Error messages:
1
Temperature sensor not connected or faulty.
Check the sensor and sensor cable for loose/bad
connections or
damage.
3
Steamer circuit board overheated
6
Contact between heater and control lost.
Check the control cable for loose/bad
connections or damage.
12
Level sensing faulty.
Check level probe wiring; clean level probe.
14
Temperature sensor faulty.
Check the sensor and sensor cable for loose/bad
connections or damage.
15
Communication problem with steamer.
Check the control cable for loose/bad
connections or damage.
For some errors, turning off power to the steamer for a brief period and then turning it back on again may correct
the error. This mostly concerns problems that have occurred with communication between the steamer and
control.
In the event of error number 3, the steam bath will be automatically switched off. When the circuit board
temperature has dropped approx. 68°F (20°C), the steam bath can be restarted. Always investigate why the
steamer overheated. It can be the result of insufficient ventilation or too high a temperature around the steam
generator.
Some errors will cause the Door indicator or Start indicator to light or blink red.
Make sure water is getting
in to the steamer and that the drain is working well
.
Contact technical support for other error codes or if an error cannot be corrected according to the above.