PURE 2.0 OPERATING INSTRUCTIONS
08/21/19
4211-1430
Page 3 of 4
When the delay is set, the Delay Indicator LED at the top of the screen will light green and the delay time LED will
flash slowly
Note:
if a bath is started after the Delay Start is set, the delay setting will be deleted.
Having a steam bath
To start a steam bath, simply press the Start key. The bath on LED should light a steady green, the
room light should turn on (the Light LED should light a steady blue), a number 1-10 LED should light a steady
blue and the Temperature setting LED should light a steady blue. A blinking 1-10 LED indicates the actual bath
temperature and a steady LED indicates the set temperature. Once the room reaches the set temperature, only
the set point LED will be lit.
While the bath is on, you may select the Duration function and a blinking 1-10 LED will indicate the time remaining
before the bath automatically shuts down.
Installing the control
Turn off power to the steamer. The PURE 2.0 connects to the AX steamer with a 50 ft (15,2 m) cable. The control
cable must be plugged directly into the steamer circuit board using one of the four jacks in the middle of the circuit
board.
Before turning on power to the generator, make sure the configuration switch is set correctly:
a)
If the generator has an electronic AutoDrain installed:
If the generator will use an
electronic AutoDrain, verify the switch in the middle of the right hand circuit board is set
as shown at left (#2 and #5 down, all other up.
b)
If the generator has only a manual drain installed:
If the generator will not use an
electronic AutoDrain, verify the switch in the middle of the right hand circuit board is set
as shown at left (#2, #4 and #6 down, all other up.
CONNECT CONTROL CABLES TO ONE OF THESE 4 JACKS
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
CONFIGURATION SWITCH
AX STEAMER – RIGHT HAND END