background image

INSTALLATION AND OPERATING INSTRUCTIONS

72-0106    02-26-16                                                                                                                                                                                                                            

                               7013482      314 SKSM 215 B

Page 1

WARNING

     SECTION 1: GENERAL INFORMATION

Do not take a sauna if using 

alcohol, drugs or 

medications.

Pregnant women or persons 

with poor health should 

consult their physician before 

using any sauna.

Caution re hazard: Do not 

use the sauna room for 

drying clothes, bathing suits, 

etc. Do not hang towels 

above heater or place any 

object other than the rocks 

supplied on the heater.  If any 

darkening of the wall around 

the heater is noticed 

discontinue sauna use 

immediately.

Inspect sauna regularly for 

required maintenance to 

heater, control and benches. 

Replace wood surfaces 

which show any signs of 

deterioration.

The heater gets extremely hot 

during operation and should 

not be touched or burns may 

result.

Minors should be adequately 

supervised whenever near a 

hot or warming sauna.

Designer “Trend" Series Sauna Heaters 
Models

 4.5

6.0

8.0 

(Type #'s 1712-45-1706, 1712-60-1706, 1712-80-1706)

 

w

ith

 Trend Control 

(Type # 1601-31 and 1601-31-1)

.

Read all instructions carefully before installation. Please leave all 
instructions and warranty with the owner. 

WARNING
Prolonged  exposure  to  elevated  temperatures  is  capable  of  inducing 
hyperthermia.  Hyperthermia  occurs  when  the  internal  temperature  of  the 
body  reaches  several  degrees  above  the  normal  body  temperature  of 
98.6°F. The symptoms of hyperthermia include an increase in the normal 
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The 
effects  of  the  hyperthermia  include  failure  to  perceive  heat,  failure  to 
recognize  the  need  to  exit  the  room,  unawareness  of  impending  hazard, 
fetal  damage  in  pregnant  women,  physical  inability  to  exit  the  room  and 
unconsciousness.

WARNING
The use of alcohol, drugs, or medication is capable of greatly increasing 
the risk of fatal hyperthermia.

These heaters are ETL approved by Intertek for permanent installations and 
electrical connections.  Built with splash proof construction, the conducting 
parts are protected against water.  All wiring must be performed in 
accordance with national and local codes.  See Diagram 2 for wire and 
room size requirements. These heaters are wall mounted.

Содержание Designer 4.5

Страница 1: ...ntrol Type 1601 31 and 1601 31 1 Read all instructions carefully before installation Please leave all instructions and warranty with the owner WARNING Prolonged exposure to elevated temperatures is ca...

Страница 2: ...STANCE B DISTANCE C DISTANCE D DISTANCE K DISTANCE Designer 4 5 3 0 3 5 8 4 0 11 1 2 23 Designer 6 0 4 0 4 5 8 5 0 11 1 2 23 Designer 8 0 5 0 5 5 8 6 0 11 1 2 23 HEATER MINIMUM WIRE SIZE Floor Area Ce...

Страница 3: ...rvice to this equipment should be performed by quali ed licensed personnel in accordance with local and national codes Do not construct sauna room so as to restrict air ow through the bottom of the he...

Страница 4: ...above the heater Insert screwdriver tip here to unsnap sensor cover from sensor Note vertical orientation of cover before removing Diagram 4 was intentionally left blank Sensor protective cover Locat...

Страница 5: ...2 3 02 26 2016 P1 P2 P3 1 3 5 7 A1 2 4 6 8 A2 X1 X2 X3 X5 X7 X4 X6 X8 X9 X10 N N H Trans former 120 Volt Light Output 2 0 Amp Max Connect L1 to terminals 1 2 and 5 Connect L2 to terminals 3 4 and 6 C...

Страница 6: ...26 2016 P1 P2 P3 1 3 5 7 A1 2 4 6 8 A2 X1 X2 X3 X5 X7 X4 X6 X8 X9 X10 N N H 2 3 Trans former 120 Volt Light Output 2 0 Amp Max 3 Phase Connection Connect L1 to terminals 1 and 2 Connect L3 to terminal...

Страница 7: ...the control and push any excess cable into wall cavity before securing control to the wall Maximum control cable length is 50 feet Remove the adhesive tape from the back of the the control place the c...

Страница 8: ...stopped Some sauna bathers enjoy the soothing effect of steam by splashing water on the heated sauna rocks Use only one dipper full approx cup at a time and keep clear of the steam as it rises off the...

Страница 9: ...and the outer wall will reduce cycling of the heater b Rocks must be placed between the elements and the wall of the rock compartment Incorrect Placement of Rocks a Loosely place rocks between the ele...

Страница 10: ...The enclosed CAUTION Reduce the risk of re caution plate must be mounted on the interior wall above the heater The heater should not be operated without its container properly lled with rocks and the...

Страница 11: ...a oor mopped and dried in a conventional manner and the duckboard thoroughly scrubbed and dried before returning to the sauna room The sauna heater should be wiped down occasionally with a damp cloth...

Страница 12: ...scale of the control The fault error code will be displayed with a constant LED light or a ashing LED light See the list below for fault codes Constant LED Fault Code ones marked with n a are not in...

Отзывы: