background image

7

Repeat OFF and ON

Programming the timer for repeat OFF and ON - when the unit is RUNNING.
 •  Perform the standard steps as described above.
 •  Repeat the above procedure while the digits are still flashing for setting the ON.
The circular time scale will be ON between 00:00 to the time set with the timer to OFF and 
from that time until 24:00. The flashing bar on the time scale indicates the real time and 
moves a segment ahead every 30 minutes. The unit will operate daily according to the timer 
setting. 

Repeat ON and OFF

Programming the timer for repeat ON and OFF - when the unit is NOT RUNNING.
 •  Perform the standard steps as described above.
 •  Repeat the above procedure while the digits are still flashing for setting the OFF.
The circular time scale will be OFF between 00:00 to the time set with the timer to ON and 
from that time until 24:00. The flashing bar on the time scale indicates the real time and 
moves a segment ahead every 30 minutes. The unit will operate daily according to the timer 
setting. 

After a power failure, or after the unit has been unplugged, you will have to program the 
timer settings again.

Cancelling the timer function

In order to cancel the timer programming press the 

 button momentarily, then it will 

return to the time display. The daily mode will be cancelled as well. The black segments in 
the circular time scale will disappear.

Programming the timer for OFF - when the unit is RUNNING. 
 •  Perform the standard steps as described above.
The circular time scale will be on between the present time to the OFF programmed time. 
The flashing bar on the time scale indicates the real time and moves a segment ahead every 
30 minutes until it reaches the OFF timer time, then the black segments in the circular time 
scale will disappear.

Air flow

On the moment the air conditioner is connected to the mains, the louvres 
open and close  and stay closed.
 • When the ON-button is pressed, the louvres open to maximum and 

return to an angle of 75° above the upper plane of the louvres housing.

 • Press the 

-button, the louvres will swing continuously up and down 

between 30° and 80° above the upper plane of the louvres housing. 

 • By pressing the 

-button again the movement will stop and the louvres 

remain in that position. The direction of the air flow is then constant.

 • When the OFF-button is pressed, the louvres close.
This way of directing the air flow is particularly convenient when using 
the remote control: a user friendly approach to your comfort.
In order to direct the air flow to a lower angle, raise the louvres housing 
by pulling it up only by the centre of its back rim.

Air outlet up, 

louvres opened

Air outlet down, 

louvres closed

Raising the 

louvres housing.

Содержание PLMB mono 12KE-410

Страница 1: ...PLMB mono blocs PLMB ENGLISH INSTRUCTION MANUAL 9KE 410 12KE 410 15KE 410 PLUS HEATER VERSIONS ...

Страница 2: ...able fuse cover that must be refitted when the fuse is replaced In the event of the fuse cover being lost or damaged the plug must not be used until a replacement cover has been obtained If the moulded mains plug is unsuitable for the socket outlet in your home or is removed for any other reason then the fuse should be removed and the cut off plug disposed of safely to prevent the hazard of electr...

Страница 3: ...nsed electrician Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to do so could result in a loss of warranty A damaged supply cord should be replaced by the manufacturer its service agent or a qualified person in order to avoid a hazard WARNING Never operate this appliance if it has a damaged cord or plug Do not lead t...

Страница 4: ...st hose Water container Remote control Controls ON OFF UP DOWN MODE TIMER SLEEP F SWING AN SPEED Display COOLING FAN HEAT HOURS MINUTES TEMPERATURE Upper air inlet Air outlet Control panel Caster wheels Lower air inlet Exhaust air outlet Cable storage Drainage point with water stopper ...

Страница 5: ...r white where included in the filter holder Place the filter fixer back in the holder Place the filter holder back in the air conditioner Do not operate the unit inside the bathroom shower or in any other very humid environment Connect the hose to the unit by turning it clockwise at least 5 turns Similarly connect the hose to the slide bar connector as far as possible Place the telescopic slide bar in...

Страница 6: ...hing any button on the control panel the backlight will switch on again Heat EH models feature a 1680 W electric heater that can heat a room on cooler days With the mode switch select set the desired temperature and the unit will heat until this temperature is reached Fan speed is selected automatically Do not place the unit near anything that could catch fire or be scorched Do not obstruct the air...

Страница 7: ...n to the time display The daily mode will be cancelled as well The black segments in the circular time scale will disappear Programming the timer for OFF when the unit is RUNNING Perform the standard steps as described above The circular time scale will be on between the present time to the OFF programmed time The flashing bar on the time scale indicates the real time and moves a segment ahead ever...

Страница 8: ... add this to your model or wish to purchase a replacement call Amcor for details NOTE The active carbon filter and the 3M Filtrete filter are delivered in a plastic packaging Don t forget to install these filters These filters take away unhealthy particles out of the room environment The filter holder on the rear of the unit can be opened The active carbon filter and 3M Filtrete filter can be installed o...

Страница 9: ...ge container Replacement filter packages are available directly from Amcor To run the unit without active carbon filter and or 3M Filtrete filter does not do any harm to the air conditioner In this case odours and unhealthy dust are not removed from the circulated air The screen filter must always be used 3M and Filtrete are trademarks of the 3M Company Under high humidity conditions it may be necessa...

Страница 10: ... decreased then turn on the unit again The remote control does not function Distance too great Make sure the remote control is correctly aimed at the control panel Remote control signal not detected by the control panel The batteries are drained Replace the batteries To correct problems that have not been described in the table and or if the recommended solutions fail to solve the problem contact ...

Страница 11: ...ies can be connected only to a supply with system impedance no more than 0 247 Ohm PLMB15KEHx 410 and PLMB15KEx 410 series can be connected only to a supply with system impedance no more than 0 110 Ohm If necessary please consult your supply authority for system impedance information red conform EN 14511 Subject to modifications without prior notice For greater precision please refer to the rating ...

Страница 12: ...ired by an unauthorised person The guarantee does not cover accidental damage misuse or consumable items such as filters The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of Amcor Limited Amcor Limited disclaims any liability for inciden...

Отзывы: