11
TECHNICAL DATA
STORAGE
Reminder:
Waste electrical products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.
Model
PLMB9KE-410
PLMB12KE-410
PLMB15KE-410
PLMB9KEH-410 PLMB12KEH-410 PLMB15KEH-410
Cooling capacity *
BTU/h
7500
9400
11300
kW
2.2
2.75
3.3
Power consumption
-Cooling
-Heating (EH only)
0.8
1.0
1.5
kW
1.75
1.68
R410A / 500
R410A / 630
-Heating element (EH only)
Mains
V / Hz / PH
220 - 240 / 50 / 1
Compressor model
rotary
Fan speeds
3 (2+1 turbo)
Thermostatic range
°C
18 - 32
Refrigerant charge
type / g
R410A / 420
Dimensions (w x h x d)
mm
500 x 840 x 415
Net weight
kg
33.1
34.3
39.3
* measu
PLMB9KEHx-410 and PLMB9KEx-410 series can be connected only to a supply with system impedance no
more than 0.383 Ohm.
PLMB12KEHx-410 and PLMB12KEx-410 series can be connected only to a supply with system impedance no
more than 0.247 Ohm.
PLMB15KEHx-410 and PLMB15KEx-410 series can be connected only to a supply with system impedance no
more than 0.110 Ohm
If necessary, please consult your supply authority for system impedance information.
red conform EN
14511
Subject to modifi cations without prior notice. For greater precision, please refer to the rating label placed on
the product.
Empty the internal water container.
Clean the screen filter.
Remove 3M Filtrete™ filter and active carbon filter.
• Remove the 3M Filtrete™ filter and active carbon filter before end of
season storage and install new filters at the beginning of the new season.
The old filters can be disposed of in the ‘Non-biological rubbish
container .
• Replacement filter packages are available from Amcor.
Put the unit in Fan Only mode for a few hours to ensure that the inside
becomes completely dry.
Store the cable as shown.
Protect the unit against dust and store in a dry place, not accessible to children.