background image

2

2

Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep 
this manual in a safe place for future reference. It describes the many benefits and advanced 
features this unique product has to offer. Before you use your new air conditioner you should 
carefully read these instructions to maximise this product’s performance. 

For over 50 years Amcor has specialised in complete indoor environmental control, 
manufacturing and marketing; dehumidifiers, portable air conditioners, coolers, air purifiers, 
ionisers and aroma therapy scent diffusers. These world class products incorporate the latest 
technological developments.

 THANK 

YOU!

For your safety please read the following information.

Warning: This appliance must be earthed.

The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse. Should 
the fuse require replacement, it must be replaced with a fuse rated at 13 amp and approved to BS1362.

The plug contains a removable fuse cover that must be refitted when the fuse is replaced. In the event 
of the fuse cover being lost or damaged, the plug must not be used until a replacement cover has been 
obtained.

If the moulded mains plug is unsuitable for the socket outlet in your home or is removed for any other 
reason, then the fuse should be removed and the cut off plug disposed of safely to prevent the hazard 
of electric shock.

There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet.

Important  

The wires in the mains lead on this appliance are coloured in 
accordance with the following code:

Green and Yellow - Earth
Blue – Neutral
Brown – Live

As the colours may not correspond with the markings 
identifying the terminals in your plug proceed as follows.

The green and yellow wire must be connected to the terminal 
in the plug which is marked with the letter E or with the earth 
symbol  

   or coloured green and yellow.

The blue wire must be connected to the terminal marked N or coloured black.

The brown wire must be connected to the terminal marked L or coloured red.

(3&&/:&--08

&BSUI

#-6&

/FVUSBM

#308/

-JWF

'64&

"NQ

$PSEDMBNQ

How to wire a 13 amp plug.

 ELECTRIC 

CONNECTION

Содержание PLMB mono 12KE-410

Страница 1: ...PLMB mono blocs PLMB ENGLISH INSTRUCTION MANUAL 9KE 410 12KE 410 15KE 410 PLUS HEATER VERSIONS ...

Страница 2: ...able fuse cover that must be refitted when the fuse is replaced In the event of the fuse cover being lost or damaged the plug must not be used until a replacement cover has been obtained If the moulded mains plug is unsuitable for the socket outlet in your home or is removed for any other reason then the fuse should be removed and the cut off plug disposed of safely to prevent the hazard of electr...

Страница 3: ...nsed electrician Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to do so could result in a loss of warranty A damaged supply cord should be replaced by the manufacturer its service agent or a qualified person in order to avoid a hazard WARNING Never operate this appliance if it has a damaged cord or plug Do not lead t...

Страница 4: ...st hose Water container Remote control Controls ON OFF UP DOWN MODE TIMER SLEEP F SWING AN SPEED Display COOLING FAN HEAT HOURS MINUTES TEMPERATURE Upper air inlet Air outlet Control panel Caster wheels Lower air inlet Exhaust air outlet Cable storage Drainage point with water stopper ...

Страница 5: ...r white where included in the filter holder Place the filter fixer back in the holder Place the filter holder back in the air conditioner Do not operate the unit inside the bathroom shower or in any other very humid environment Connect the hose to the unit by turning it clockwise at least 5 turns Similarly connect the hose to the slide bar connector as far as possible Place the telescopic slide bar in...

Страница 6: ...hing any button on the control panel the backlight will switch on again Heat EH models feature a 1680 W electric heater that can heat a room on cooler days With the mode switch select set the desired temperature and the unit will heat until this temperature is reached Fan speed is selected automatically Do not place the unit near anything that could catch fire or be scorched Do not obstruct the air...

Страница 7: ...n to the time display The daily mode will be cancelled as well The black segments in the circular time scale will disappear Programming the timer for OFF when the unit is RUNNING Perform the standard steps as described above The circular time scale will be on between the present time to the OFF programmed time The flashing bar on the time scale indicates the real time and moves a segment ahead ever...

Страница 8: ... add this to your model or wish to purchase a replacement call Amcor for details NOTE The active carbon filter and the 3M Filtrete filter are delivered in a plastic packaging Don t forget to install these filters These filters take away unhealthy particles out of the room environment The filter holder on the rear of the unit can be opened The active carbon filter and 3M Filtrete filter can be installed o...

Страница 9: ...ge container Replacement filter packages are available directly from Amcor To run the unit without active carbon filter and or 3M Filtrete filter does not do any harm to the air conditioner In this case odours and unhealthy dust are not removed from the circulated air The screen filter must always be used 3M and Filtrete are trademarks of the 3M Company Under high humidity conditions it may be necessa...

Страница 10: ... decreased then turn on the unit again The remote control does not function Distance too great Make sure the remote control is correctly aimed at the control panel Remote control signal not detected by the control panel The batteries are drained Replace the batteries To correct problems that have not been described in the table and or if the recommended solutions fail to solve the problem contact ...

Страница 11: ...ies can be connected only to a supply with system impedance no more than 0 247 Ohm PLMB15KEHx 410 and PLMB15KEx 410 series can be connected only to a supply with system impedance no more than 0 110 Ohm If necessary please consult your supply authority for system impedance information red conform EN 14511 Subject to modifications without prior notice For greater precision please refer to the rating ...

Страница 12: ...ired by an unauthorised person The guarantee does not cover accidental damage misuse or consumable items such as filters The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of Amcor Limited Amcor Limited disclaims any liability for inciden...