background image

 

 

Drain connector

 

Drain plug cap

 

  

WATER-DRAINAGE

 

 

MANUAL DRAINAGE

 

When the internal water tank is full the unit will stop working.

 

Shut off the unit and unplug. Avoid moving the model abruptly as 
this may cause water to spill from the internal tank.

 

Place a tray under the water plug.

 

Unscrew

 the Drain plug cap and remove the rubber stopper - water 

will drain from the internal tank.

 

Put the rubber stopper back and screw the drain plug cap back into 
place.

 

 
CONTINUOUS DRAINAGE:

 

Unscrew the drain plug cap and remove the rubber stopper. Fit the 
drain connector within the cap

 

Connect a suitable pipe to the water outlet to remove the water out 
continuously.

 

 

Note: This model is self-evaporative, which reduces the need to empty 
the water tank.

 

If the unit is vented correctly most of the water is reused to cool the 
condenser coils and any excess is evaporated.

 

Please do not use continuous drainage if you intend to use

 

the self-

evaporate facility.

 

 

  

MAINTENANCE

 

 

CLEANING

 

Turn off the unit and unplug from the mains before cleaning or performing any maintenance.

 

CLEAN THE SURFACE

 

Clean the plastic housing with a duster or a soft wet cloth.

 

Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause 
irreversible damage.

 

AIR FILTER CLEANING

 

Clean the air filters every 2 weeks. If the air filter is blocked with dust, the performance of 
the unit will be significantly affected.

 

Pull out the top and bottom filters as pictured below

 

Wash the air filters by immersing them in warm (about 40

) water with a neutral detergent.

 

Rinse it and then dry it thoroughly.

 

Carefully re-install air filters

 

END OF SEASON MAINTENANCE

 

1.

 Pull out the plug from the drainage hole and empty the internal tank. You should ensure 

the tank is fully drained by leaning the unit backwards.

 

2.

 Then switch the unit to Fan mode,

 

3.

 Keep the unit in this mode for half day. Doing this helps to keep the inside of the unit dry 

and prevents mold developing

 

4.

 Turn off the unit and unplug

 

5.

 Ensure the water tank is empty before replacing the rubber bung and drain cap.

 

6.

 Coil the wire and bind it together, then put it into the accessories space.

 

7.

 Separate the air-exhausted pipe and store it safely.

 

8.

 Cover the unit and keep it in a dry place.

 

9.

 Take the batteries out of remote control and store, or dispose, them safely

 

 

Drain plug cap

 

Rubber stopper

 

Drain pipe  
(size: 10 mm)

 

Содержание AC12

Страница 1: ...AC12 AC12HP USER MANUAL Portable Air Conditioner ...

Страница 2: ...ers coolers air purifiers ionisers and aroma therapy scent diffusers These world class products incorporate the latest technological developments QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER Exposed to the weather outdoors Near water If the power cable wires are frayed or cut Where small children may be left unattended If an extension lead may become overloaded Where the...

Страница 3: ...ove and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Do not clean the unit by spraying it or...

Страница 4: ...nce should not be installed in laundry or wet rooms Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills For maximum performance the minimum distance from a wall or objects should be minimum 50cm Keep the filters clean Under normal conditions filters should only need cleaning once every three weeks approximately Since the filters remove...

Страница 5: ...in screw cap 10 Power cord Check that all accessories are in the box and please read the instructions manual before assembling the unit 1 Extendable slide bar 2 Screw washer nut for slide bar 3 Extendable exhaust hose up to 1 5 meters 4 Hose connector 5 Fishtail adapter 6 10mm Drain pipe AC12HP only 7 Drain connector AC12HP only 8 Remote control ...

Страница 6: ...ls 3 With the hose and fishtail adaptor connected to the unit push the end of the fishtail adaptor into the slot in the slide bar NOTES To ensure efficient operation the opening should be as small as possible The best form of installation is through a wall duct The unit will need to be externally in heating mode AC12HP only ideally through the wall By properly venting you expel cold air from your ...

Страница 7: ...s to adjust the desired temperature between 16 to 31 Press SPEED to select fan speed high medium and low DEHUMIDIFY MODE Press MODE to select dehumidify mode the dehumidifying mode indicator will be lit When using dehumidify mode the sleep function cannot be used and the fan speed is low The dehumidifier does not need to be externally vented but continuous drainage should be set up for the moistur...

Страница 8: ...e unit on off 2 TIMER Press to set the timer Once set selected duration will flash 5 times as confirmation Under power on or standby mode press this button to setup the on off timer between 1 24 3 Down Press to decrease the desired temperature or the timer duration after pressing the timer button 4 Mode Press to choose between cooling heating AC12HP only dehumidifying or fan modes 5 Up Press to in...

Страница 9: ...ean the plastic housing with a duster or a soft wet cloth Do not use chemical solvents such as benzene alcohol or gasoline as they may cause irreversible damage AIR FILTER CLEANING Clean the air filters every 2 weeks If the air filter is blocked with dust the performance of the unit will be significantly affected Pull out the top and bottom filters as pictured below Wash the air filters by immersi...

Страница 10: ...ibrations Compressor does not work Overheating protection is active Check the vent pipe is not restricted Restart the unit after 10 minutes when compressor has cooled Remote control doesn t work Operating distance is too far Move remote control closer to the unit and make sure it aims at the air outlet grille Control panel has not received the signal from remote control The batteries are flat Repl...

Страница 11: ...r local household waste recycling centres TECHNICAL DATA Model AC12 AC12HP Cooling Capacity KW BTU 3 51 12000 Heating Capacity KW BTU 2 93 10000 Cooling Rated Input W 1500 Heating Rated Input W 1270 Mains 220 240 V 50 Hz Current Cooling Heating A 5 97 5 62 Refrigerant R410A Moisture Removal L Day 50 EER Rating A Permitted Excessive Operating Pressure Suction Discharge MPa 0 8 3 2 Maximum Allowable...

Страница 12: ...ng upright for at least 2 hrs Is the unit plugged into the mains Is the fuse OK Switch the unit on and wait three minutes to see if the issue is resolved Check whether the water tank is full If the unit still fails to operate call 0871 620 1057 Office hours 9AM 5PM Monday to Friday Unit J6 Lowfields Way Elland West Yorkshire HX5 9DA ...

Отзывы: