TECHNICAL DATA

 

 

 

Model

 

AC12/AC12HP

 

Cooling Capacity

 

KW/BTU

 

3.51/12000

 

Heating Capacity

 

KW/BTU

 

2.93/10000

 

Cooling Rated Input

 

W

 

1500

 

Heating Rated Input

 

W

 

1270

 

Mains

 

 

220-240 V / 50 Hz

 

Current Cooling / Heating

 

A

 

5.97/5.62

 

Refrigerant

 

 

R410A

 

Moisture Removal

 

L/Day

 

50

 

EER Rating

 

 

A

 

Permitted Excessive Operating 
Pressure Suction / Discharge

 

 

MPa

 

 

0.8/3.2

 

Maximum Allowable Pressure

 

MPa

 

5.0

 

Compressor

 

 

Rotary

 

Fan Speed

 

 

3

 

 

Noise

 

 

dB(A)

 

Sound Pressure

 

≤54

 

Sound Power

 

≤65

 

Thermostat

 

 

16-31

 

Timer

 

h

 

1-24

 

 

Fuse Parameter

 

 

Type: FSD / 50F

 

Voltage: AC 250V;F;3.15AL

 

Net Weight

 

kg

 

29

 

Dimension(L*D*H)

 

mm

 

400 x 370 x 800

 

Unit must be vented outside when in Air Cooling mode. For the purposes of EU regulation 
EN12102 this is a local air conditioner and produces less than 65dB(A) sound energy

 

Содержание AC12

Страница 1: ...AC12 AC12HP USER MANUAL Portable Air Conditioner ...

Страница 2: ...ers coolers air purifiers ionisers and aroma therapy scent diffusers These world class products incorporate the latest technological developments QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER Exposed to the weather outdoors Near water If the power cable wires are frayed or cut Where small children may be left unattended If an extension lead may become overloaded Where the...

Страница 3: ...ove and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Do not clean the unit by spraying it or...

Страница 4: ...nce should not be installed in laundry or wet rooms Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills For maximum performance the minimum distance from a wall or objects should be minimum 50cm Keep the filters clean Under normal conditions filters should only need cleaning once every three weeks approximately Since the filters remove...

Страница 5: ...in screw cap 10 Power cord Check that all accessories are in the box and please read the instructions manual before assembling the unit 1 Extendable slide bar 2 Screw washer nut for slide bar 3 Extendable exhaust hose up to 1 5 meters 4 Hose connector 5 Fishtail adapter 6 10mm Drain pipe AC12HP only 7 Drain connector AC12HP only 8 Remote control ...

Страница 6: ...ls 3 With the hose and fishtail adaptor connected to the unit push the end of the fishtail adaptor into the slot in the slide bar NOTES To ensure efficient operation the opening should be as small as possible The best form of installation is through a wall duct The unit will need to be externally in heating mode AC12HP only ideally through the wall By properly venting you expel cold air from your ...

Страница 7: ...s to adjust the desired temperature between 16 to 31 Press SPEED to select fan speed high medium and low DEHUMIDIFY MODE Press MODE to select dehumidify mode the dehumidifying mode indicator will be lit When using dehumidify mode the sleep function cannot be used and the fan speed is low The dehumidifier does not need to be externally vented but continuous drainage should be set up for the moistur...

Страница 8: ...e unit on off 2 TIMER Press to set the timer Once set selected duration will flash 5 times as confirmation Under power on or standby mode press this button to setup the on off timer between 1 24 3 Down Press to decrease the desired temperature or the timer duration after pressing the timer button 4 Mode Press to choose between cooling heating AC12HP only dehumidifying or fan modes 5 Up Press to in...

Страница 9: ...ean the plastic housing with a duster or a soft wet cloth Do not use chemical solvents such as benzene alcohol or gasoline as they may cause irreversible damage AIR FILTER CLEANING Clean the air filters every 2 weeks If the air filter is blocked with dust the performance of the unit will be significantly affected Pull out the top and bottom filters as pictured below Wash the air filters by immersi...

Страница 10: ...ibrations Compressor does not work Overheating protection is active Check the vent pipe is not restricted Restart the unit after 10 minutes when compressor has cooled Remote control doesn t work Operating distance is too far Move remote control closer to the unit and make sure it aims at the air outlet grille Control panel has not received the signal from remote control The batteries are flat Repl...

Страница 11: ...r local household waste recycling centres TECHNICAL DATA Model AC12 AC12HP Cooling Capacity KW BTU 3 51 12000 Heating Capacity KW BTU 2 93 10000 Cooling Rated Input W 1500 Heating Rated Input W 1270 Mains 220 240 V 50 Hz Current Cooling Heating A 5 97 5 62 Refrigerant R410A Moisture Removal L Day 50 EER Rating A Permitted Excessive Operating Pressure Suction Discharge MPa 0 8 3 2 Maximum Allowable...

Страница 12: ...ng upright for at least 2 hrs Is the unit plugged into the mains Is the fuse OK Switch the unit on and wait three minutes to see if the issue is resolved Check whether the water tank is full If the unit still fails to operate call 0871 620 1057 Office hours 9AM 5PM Monday to Friday Unit J6 Lowfields Way Elland West Yorkshire HX5 9DA ...