MOUNTING THE SD17040C

Outline Drawing

There are two ways to mount the SD17040C.

!

The first method is with four #10-32 screws into its side panel.

!

The second method is by the mounting tabs.  Mounting tabs are for #6 screws.

Minimum and maximum screw lengths should be observed to prevent a screw from 
shorting to the PC Board.

There are airflow holes in the top and bottom of the enclosure.  To ensure adequate convec-
tional airflow, the driver must be mounted in the orientation shown in the drawing.  

Grounding

The SD17040C must be grounded for proper operation.  The 

GND 

connection on the power connector is con-

nected to the SD17040C enclosure and is a sufficient grounding point for most applications.  When mounting 
the SD17040C on a surface that is electrically conductive and grounded, you should also take steps to ensure 
that the two are electrically bonded together.  If necessary, remove paint for the bolt mounting surfaces of the 
panel to ensure adequate electrical bonding.

Airflow and Wiring Space

To ensure adequate airflow and wiring space, you need two inches (50 mm) of space above and below the 
driver, one and one-half inches (37 mm) of space to the left and right of the driver, and one inch (25 mm) of 
space in front of the driver.  These dimensions are typical for convectional cooling.  If you have an active 
cooling system such as enclosure fans, you will be able to mount the drivers closer together.

DIR/CCW +
DIR/CCW

STEP/CW

DISABLE

FAULT

STEP/CW

DISABLE

FAULT

INTERLOCK

B CTAP

EARTH GND

A CTAP

INTERLOCK

B

B

A

A

GND

N

L

STEP/FAULT

POWER

+

+

+

AC POWER

95 – 132 V

AC

50/60 Hz

 2.05" 

(52.1) 

1.10"

(27.9)

0.118"

(4.78)

0.152" 

(3.86)

 

dia.

0.312"

 

(7.92)

 

dia.

6.71"

(170.4)

 

0.152"

(3.86)

        typ.

1.000"

(25.40)

0.60" 

(15.2)

6.15"

(156.2)

4.00" (101.6)

4.000"

(101.60)

1.073"

(27.25)

0.875"

(22.23)

7.00"

(177.8)

2.750" (69.85)

#10-32 UNF-2B.

Four places.

Min. screw length = 0.31" 

(7.9)

 + thickness of mounting panel.

Max. screw length = 0.62" 

(15.8)

 + thickness of mounting panel.

Содержание SD17040C

Страница 1: ...s e r M anual Manual 940 0S110 Table of Contents General Information 2 Introducing the SD17040C 3 Specifications 4 Mounting the SD17040C 5 Switch Settings 6 Connecting Your Controller 7 Connecting You...

Страница 2: ...at its option repair or replace free of charge any equipment covered by this warranty which is returned shipping charges prepaid within eighteen months from date of invoice and which upon examination...

Страница 3: ...uitry Back EMF Protection Circuity Programmable Step Resolution from 200 to 50 800 steps per turn Programmable Idle Current Reduction Programmable Current Loop Gain Programmable Pulse Train Input Step...

Страница 4: ...Motor Current Switch selectable from 1 0 to 4 0ARMS in 0 1 Amp steps Idle Current Reduction Switch selectable to Not reduced To 69 To 50 or To 0 Motor current is reduced to selected level if a step p...

Страница 5: ...so take steps to ensure that the two are electrically bonded together If necessary remove paint for the bolt mounting surfaces of the panel to ensure adequate electrical bonding Airflow and Wiring Spa...

Страница 6: ...0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 1 1 0 0 0 0 0 0 1 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 0...

Страница 7: ...lses The active state of the Disable Input is set by switch SB1 4 RLD An additional load resistor may be required on some PLC outputs to improve switching time A symptom of this problem is that the mo...

Страница 8: ...e and is not ready to accept pulses Both ends of the output are uncommitted so it can be wired as a sourcing or sinking output The figure shows a typical connection as a sourcing output RLIMIT A resis...

Страница 9: ...TAP B B EARTH GND A CTAP INTERLOCK A A 8 LEAD MOTOR Eight Lead Series Connected Motor Case INTERLOCK B CTAP B B EARTH GND A CTAP INTERLOCK A A 8 LEAD MOTOR Eight Lead Parallel Connected Motor Case INT...

Страница 10: ...r itself B Phase Ground Short One of the motor s windings is shorted to earth ground The EARTH GND terminal of the Motor Connector is used as the reference point The fault can be in the motor cable or...

Страница 11: ...for your system Turn off all of the switches in switch bank 2 and then verify that the motor current is set correctly and the motor is attached to the driver Cycle power to the driver The STEP FAULT...

Страница 12: ...ne turn While the turn is in progress the STEP LED should blink Verify that the motor rotated in the correct direction for one complete turn If you are using an optical encoder or other position feedb...

Страница 13: ...be active The active state power applied or power removed is set by DIP switch SB1 4 This switch may be set incorrectly 2 The Idle Current Reduction may be set to its To 0 setting With this setting cu...

Страница 14: ...he driver is config ured for the Step Direction format the motor will rotate counter clock wise when the driver receives CW pulses and it will not rotate at all when the driver receives CCW pulses If...

Страница 15: ......

Страница 16: ...VANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC ADVANCED MICRO CONTROLS INC ADVANCED MICRO CONTROLS INC ADVANCED MICRO CONTROLS INC 20 GEAR DRIVE TERRYVILLE CT 06786 T 860 585 1254 F 860 584 1973...

Отзывы: