background image

ADVANCED MICRO CONTROLS INC.

 GENERAL INFORMATION

Important User Information

The products and application data described in this manual are useful in a wide variety of different applications.  
Therefore, the user and others responsible for applying these products described herein are responsible for deter-
mining the acceptability for each application.  While efforts have been made to provide accurate information 
within this manual, AMCI assumes no responsibility for the application or the completeness of the information 
contained herein.
UNDER NO CIRCUMSTANCES WILL ADVANCED MICRO CONTROLS, INC. BE RESPONSIBLE OR 
LIABLE FOR ANY DAMAGES OR LOSSES, INCLUDING INDIRECT OR CONSEQUENTIAL DAM-
AGES OR LOSSES, ARISING FROM THE USE OF ANY INFORMATION CONTAINED WITHIN THIS 
MANUAL, OR THE USE OF ANY PRODUCTS OR SERVICES REFERENCED HEREIN.
No patent liability is assumed by AMCI, with respect to use of information, circuits, equipment, or software 
described in this manual.
The information contained within this manual is subject to change without notice.
This manual is copyright 2009 by Advanced Micro Controls Inc.  You may reproduce this manual, in whole or 
in part, for your personal use, provided that this copyright notice is included.  You may distribute copies of this 
complete manual in electronic format provided that they are unaltered from the version posted by Advanced 
Micro Controls Inc. on our official website: www.amci.com.  You may incorporate portions of this documents in 
other literature for your own personal use provided that you include the notice “Portions of this document copy-
right 2009 by Advanced Micro Controls Inc.” You may not alter the contents of this document or charge a fee 
for reproducing or distributing it.

Standard Warranty

ADVANCED MICRO CONTROLS, INC. warrants that all equipment manufactured by it will be free from 
defects, under normal use, in materials and workmanship for a period of [18] months.  Within this warranty 
period, AMCI shall, at its option, repair or replace, free of charge, any equipment covered by this warranty 
which is returned, shipping charges prepaid, within eighteen months from date of invoice, and which upon 
examination proves to be defective in material or workmanship and not caused by accident, misuse, neglect, 
alteration, improper installation or improper testing.
The provisions of the “STANDARD WARRANTY” are the sole obligations of AMCI and excludes all other 
warranties expressed or implied.  In no event shall AMCI be liable for incidental or consequential damages or 
for delay in performance of this warranty.

Returns Policy

All equipment being returned to AMCI for repair or replacement, regardless of warranty status, must have a 
Return Merchandise Authorization number issued by AMCI.  Call (860) 585-1254 with the model number and 
serial number (if applicable) along with a description of the problem.  An “RMA” number will be issued.  
Equipment must be shipped to AMCI with transportation charges prepaid.  Title and risk of loss or damage 
remains with the customer until shipment is received by AMCI.

24 Hour Technical Support Number

24 Hour technical support is available on this product.  Start at our website, www.amci.com if you have inter-
net access.  Product documentation and FAQ’s  are available on the site that answer most common questions.  

If you require additional technical support, call (860) 583-7271.  Your call will be answered by the factory 
during regular business hours, Monday through Friday, 8AM - 5PM Eastern.  During non-business hours an 
automated system will ask you to enter the telephone number you can be reached at.  Please remember to 
include your area code.  The system will page an engineer on call.  Please have your product model number 
and a description of the problem ready before you call. 

We Want Your Feedback

Manuals at AMCI are constantly evolving entities.  Your questions and comments on this manual are both 
welcomed and necessary if this manual is to be improved.  Please direct all comments to: Technical Docu-
mentation, AMCI, 20 Gear Drive, Terryville CT 06786, or fax us at (860) 584-1973.  You can also e-mail 
your questions and comments to [email protected]

Содержание SD17040C

Страница 1: ...s e r M anual Manual 940 0S110 Table of Contents General Information 2 Introducing the SD17040C 3 Specifications 4 Mounting the SD17040C 5 Switch Settings 6 Connecting Your Controller 7 Connecting You...

Страница 2: ...at its option repair or replace free of charge any equipment covered by this warranty which is returned shipping charges prepaid within eighteen months from date of invoice and which upon examination...

Страница 3: ...uitry Back EMF Protection Circuity Programmable Step Resolution from 200 to 50 800 steps per turn Programmable Idle Current Reduction Programmable Current Loop Gain Programmable Pulse Train Input Step...

Страница 4: ...Motor Current Switch selectable from 1 0 to 4 0ARMS in 0 1 Amp steps Idle Current Reduction Switch selectable to Not reduced To 69 To 50 or To 0 Motor current is reduced to selected level if a step p...

Страница 5: ...so take steps to ensure that the two are electrically bonded together If necessary remove paint for the bolt mounting surfaces of the panel to ensure adequate electrical bonding Airflow and Wiring Spa...

Страница 6: ...0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 1 1 0 0 0 0 0 0 1 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 0...

Страница 7: ...lses The active state of the Disable Input is set by switch SB1 4 RLD An additional load resistor may be required on some PLC outputs to improve switching time A symptom of this problem is that the mo...

Страница 8: ...e and is not ready to accept pulses Both ends of the output are uncommitted so it can be wired as a sourcing or sinking output The figure shows a typical connection as a sourcing output RLIMIT A resis...

Страница 9: ...TAP B B EARTH GND A CTAP INTERLOCK A A 8 LEAD MOTOR Eight Lead Series Connected Motor Case INTERLOCK B CTAP B B EARTH GND A CTAP INTERLOCK A A 8 LEAD MOTOR Eight Lead Parallel Connected Motor Case INT...

Страница 10: ...r itself B Phase Ground Short One of the motor s windings is shorted to earth ground The EARTH GND terminal of the Motor Connector is used as the reference point The fault can be in the motor cable or...

Страница 11: ...for your system Turn off all of the switches in switch bank 2 and then verify that the motor current is set correctly and the motor is attached to the driver Cycle power to the driver The STEP FAULT...

Страница 12: ...ne turn While the turn is in progress the STEP LED should blink Verify that the motor rotated in the correct direction for one complete turn If you are using an optical encoder or other position feedb...

Страница 13: ...be active The active state power applied or power removed is set by DIP switch SB1 4 This switch may be set incorrectly 2 The Idle Current Reduction may be set to its To 0 setting With this setting cu...

Страница 14: ...he driver is config ured for the Step Direction format the motor will rotate counter clock wise when the driver receives CW pulses and it will not rotate at all when the driver receives CCW pulses If...

Страница 15: ......

Страница 16: ...VANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC ADVANCED MICRO CONTROLS INC ADVANCED MICRO CONTROLS INC ADVANCED MICRO CONTROLS INC 20 GEAR DRIVE TERRYVILLE CT 06786 T 860 585 1254 F 860 584 1973...

Отзывы: