20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
43
TASK 2
S
ET
THE
IP A
DDRESS
AND
P
ROTOCOL
2.1 Determine the Best Method for Setting the IP Address
There are three methods for setting the IP address on an NX2A4E2. Table T2.1 below outlines the available
methods and when you can use them.
Table T2.1 Methods for Setting the IP Address
There is a MAC address label on each NX2A4E2 which has a writable surface. There is room
on the label for writing the programmed IP address of the unit. It is a best practice to use this
label to document the IP address of the unit in case it is ever repurposed.
In order to conform to the ODVA specification for EtherNet/IP, the NX2A4E2 also supports
the DHCP protocol. You will need an EtherNet/IP DHCP server, such as the one available
from Rockwell Automation, in order to use this protocol. It is supported, but AMCI encour-
ages you to use the embedded web server if your company policy prevents you from installing
third-party software, such as the AMCI NET Configurator.
2.2a Use Factory Default Settings
The factory default address for the NX2A4E2 is 192.168.0.50 with a subnet mask of 255.255.255.0. The eas-
iest way to verify this address is with the ping command as described in
Configuring Network Interfaces
which starts on page 29.
https://www.wireshark.org/
) can be used to determine the address of the unit.
Task Complete
This section is intended for the engineer or technician responsible for setting the
IP address of an AMCI NX2A4E2.
Method
Restrictions
Section
1) The machine must use 192.168.0.xxx subnet.
2) The 192.168.0.50 address must be available.
1) The machine must use 192.168.0.xxx subnet.
No restrictions on use. This is the preferred method.
The internal webserver can be used to set the
NX2A4E2 to any IPv4 address. The IP address and
protocol will be stored in nonvolatile memory and
used on subsequent power-ups.
No restrictions on use. The software can be used to
set the NX2A4E2 to any IPv4 address. The IP
address and protocol choice will be stored in non-
volatile memory and used on subsequent power-ups.
The software utility can also be used to program the
NX2A4E2 and monitor data from it.
Содержание NEXUS NX2A4E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0N090 E2 Technology...
Страница 16: ...NX2A4E2 INTRODUCTION NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 16 Notes...
Страница 28: ...DATA FORMATS NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 28 Notes...
Страница 52: ...PROTOCOL SPECIFIC INFORMATION NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 52 Notes...
Страница 56: ...INSTALLING AN EDS FILE EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 56 Notes...
Страница 66: ...ETHERNET IP EXPLICIT MESSAGING EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 66 Notes...
Страница 70: ...MODBUS TCP CONFIGURATION Modbus TCP Protocol ADVANCED MICRO CONTROLS INC 70 Notes...
Страница 76: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...