ISIDE 130

ISIDE is a 105 dB power auto supplied sounder could be configured as positive missing/giving or negative missing/

giving. It features a low consuption led flasher and a  STAND BY LED. The STAND BY indicator is flashing constant at 

1 sec. the LED flasher to indicate that the system is powered and running.

ENGLISH

Nominal Supply Voltage: 

 

 

 

 

13,8 Vcc 

Functioning Voltage Limits:            

 

 

 

11 ¸ 15 Vcc 

Maximum Current Consumption: 

   

 

 

150mA

Stand-by Current Consumption:  

 

 

 

8 mA

Sound Pressure (Vn=13,8V ):        

 

 

 

Type = TONE   105 dB(A) at 1 m

Sound and Light Timing without control:   

 

 

5’ ± 20%

Back-up Battery: 

 

             

 

 

12 V  , 2,2 Ah

Dimensions:           

 

 

 

 

 

330mm(L) x 220mm(H) x 60mm(P)

Weight:  

 

 

                   

 

 

700g

Working Temperature:                 

 

 

 

- 40 °C ¸ + 60 °C

TECHNICAL SPECIFICATIONS

TAMPER: 

N.C. Antiopening and Tearing Off Contact 

 - :

 13,8 V  Supply ( Nominal )

S : 

Trig Terminal

Battery: 

Battery

 

charge terminal (12V 2.2Ah)

DIP 1

ON =  STAND BY MODE ENABLE 

DIP 2

DIP 3

OFF

OFF

Missing positive

ON

OFF

Giving positive

OFF

ON

giving negative

ON

ON

Missing negative

The system also provides tha alarm signal, when it is absent one of the power cable.

L’installazione  deve essere eseguita a regola d’arte da personale specializzato.

Il produttore declina ogni responsabilità nel caso  in cui il prodotto venga manomesso da persone non autorizzate. 

Si raccomanda di verificare il corretto funzionamento  del sistema d’allarme almeno una volta al mese, tuttavia un sistema 

di allarme  elettronico  affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situa-

zioni si verifichino.
Installation must be carried out following the local installation norms by qualified personnel. 

The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.

It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and 

due to, but not limited to, any or all of the following: tampering,  electrical or communication disruption or improper use,  it 

is possible for the product/system to fail to prevent burglary, rubbery, fire or otherwise. A properly installed and maintained 

alarm system can only reduce the risk that this happens. 