background image

ENGLISH

 

1. INTRODUCTION

 

IF16L 

is a curtain pir sensor, can create a barrier of protection useful for doors and windows. 

Is equipped with some special features that make it interesting to the sensor:

 

has a high power led light 

Has a system of recognition of the alarm direction 

It has a buzzer with different sounds depending on the direction of the violation 

It has a delay system activation 

2. FUNCTIONS DESCRIPTION

 

High power led light: 

the sensor is equipped with a high-efficiency LED that is used as a lamp 

for different functions:

 

As emergency lamp when the terminal LAMP is given a negative via open collector out 

As presence light if it is associated (duration light 40 

delay system activation (dip4 - dip5): 

Turning ON the DIP introduces a time delay between the 

instant of the sensor detects the movements and the instant at which trigger the alarm relay. After 
the first violation, the sensor will count the set time, after this time and for more 10 sec. there will be 
some movement, turn in alarm, if after the set time there will be no movements, the sensor will go 
into reset. (Possibility to enter the secured area without disarm the system, and minimum probability 

Содержание IF16L

Страница 1: ...korzystywana do uzyskania dostępu do chronionej strefy bez konieczności rozbrajania systemu Sygnalizacja akustyczna naruszenia Czujka jest wyposażona w sygnalizację dźwiękową w przypadku przejścia przez barierę gdy jest podłączona wytwarza różne dźwięki w zależności od kierunku alarmu UWAGA dokładnie rozpoznanie kierunku alarmu odbywa się dzięki umieszczeniu prawidłowej płytki separacyjnej w socze...

Страница 2: ...ych konfiguracjach od góry od dołu lub z boku W celu poprawnego wykorzystania tej funkcji rozpoznawania kierunku naruszenia oprócz ustawienia przełącznika DIP7 i DIP8 należy również odpowiednio założyć soczewkę i ustawić separator wiązki 4 INSTALACJA Wybierz miejsce instalacji czujki zamocuj czujkę za pomocą otworów do mocowania Kabel może być przeprowadzony przez mały otwór jak na rysunku lub jeś...

Страница 3: ...macje na temat elementów regulacyjnych wraz z opisem dostępnych funkcji znajdują się w dalszej części instrukcji 7 Zamknąć pokrywę czujnika 8 Podłączyć napięcie zasilania i zaczekać aż dioda w czujnika przestanie migać 5 START I KALIBRACJA Po podłączeniu czujnik potrzebuje około 40 sekund na start i kalibrację W tym czasie naruszenia nie są sygnalizowane Działanie bez ustawień kiedy czujka jest ak...

Страница 4: ...ozpoznawanie kierunku alarmu dip7 dip8 Czujnik IF16L wyposażony został w funkcje rozpoznawania kierunku z którego jest naruszany Dzięki tej funkcji możliwe jest zdefiniowanie kiedy ma być generowany alarm Do załączenia tej funkcji służy przełącznik DIP7 W pozycji DIP7 OFF alarm jest generowany niezależnie od kierunku naruszenia natomiast w pozycji DIP7 ON alarm jest generowany tylko przy naruszeni...

Страница 5: ... LED that is used as a lamp for different functions As emergency lamp when the terminal LAMP is given a negative via open collector out As presence light if it is associated duration light 40 delay system activation dip4 dip5 Turning ON the DIP introduces a time delay between the instant of the sensor detects the movements and the instant at which trigger the alarm relay After the first violation ...

Страница 6: ...e to re cross the active part without the gene ration of the alarm This time is 2 minutes after which the sensor will return ready This feature allows a user to look out the window or out on the terrace without causing alarm when the system is armed Clearly if the direction of crossing is from outside to inside the sensor will trigger in alarm requires blade separator see figure Note you can choos...

Страница 7: ...ht for 40 DIP 7 alarm from all direction Alarm from one direction DIP 8 1 2 alarm 2 1 alarm To use the directional system optimally you need to be inserted into the lens on the pyroelectric element separator see figure and install it paying attention to the direction selection dip swtch8 4 INSTALLATION Chooses uitaDieibcatiwT h The cable can go from a tiny hole next to the terminals or if the sect...

Страница 8: ...olds After this time the sensor is still ready with lamp in ON mode Each new violation prolong the time of the lamp for 40 recovery time by the alarm is 10 seconds Thus the sensor works correctly even with the lamp on When the lamp is turned off you will have a new calibration of the duration of 20 seconds In case of violations during the calibration time after 30 seconds the sensor trig in alarm ...

Страница 9: ...m 25 C to 55 C RFI Protezione Protection 10 V m 20 1000 MHz Led WALK TEST MW and PIR S Cover Housing ABS Dimensioni Dimensions L145 x H37 x P30 mm Installation must be carried out following the local installation norms by qualified personnel The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product system It is recommended to test the operation of the...

Отзывы: