Eth-SM
The set of the subnet mask used by your network.
Communication settings
Please note:
User must power cycle (reset) the unit for this settings to take effect.
DEVICE ID:
This control assigns a device ID from 1 to 16 to the unit. This ID is only useful when a network of
more than 1 unit is used in conjunction with 1 or more DSP 88.
BAUD RATE:
It sets the baud rate of the serial communication. AMC DSP Software Control uses a baud rate
of 115200, it should be left unchanged for most users.
NETWORK ID:
This control assigns a network ID from 0 to 60000 to the unit. This ID is used for future
network expansion only, please leave it at 0.
Security lock and unlock
The password is 4 characters in length. The factory default of a new unit does not require a password. The
device can be protected for unauthorized parameter and /or system abuse. The security settings can be
controlled and stored in the device with the AMC DSP Software Control only. When the correct password is
entered in the device all the locks are disabled. After reentering the password or power cycling the device,
the locks are automatically enabled again.