Display

Max. resolution 

640*480

Response time 

15ms

Maximum latency from camera 

< 200ms

Orientation 

Landscape

Display type 

6.5” colour TFT LCD

Brightness control 

Yes,  (“+” / ”-“)

Contrast control 

Yes,  (“+” / ”-“)

Start up time 

About 10 seconds

Electrical power

Power requirement  

 

12V 2.5A DC input

Battery type 

7.2V 2200mAh Li-ion battery

Operating environment

Temperature 

10 ~ 40°C (50 ~ 104°F)

Relative humidity 

30 ~ 85%

IP Protection Classification System 

The Ambu® aScope™ Monitor is classified IP50.

Connection

Video signal standard 

NTSC

Video out connection 

3.5mm jack socket

Video out cable 

3.5mm jack plug to RCA jack plug

Storage

Temperature

 

10 ~ 40°C (50 

~

 104°F)

Relative humidity 

10 ~ 90% 

Mounting interface

Mounting interface standard 

 VESA MIS-D, 75 C, VESA FDMI compliant display, Part D, with 

 

centre located mounting interface

Fixture

Mounting interface 

75mm (2.96”)

Fits poles with thicknesses

 

10mm ~ 45mm (0.4 ~ 1.8”)

Table 2 - Specification for the Ambu® aScope™ Monitor

Ambu® aScope™ power supply 

Dimensions

Weight 

245g (0.54lbs)

Electrical power

Power requirement  

100 - 240V AC; 50-60Hz; 0.6A

Power out 

12V DC; 2.08A

Operating environment

Temperature 

10 ~ 40°C (50 ~ 104°F)

Storage

Temperature 

10 ~ 40°C (50 ~ 104°F)

Relative humidity 

10 ~ 90% 

Содержание aScope

Страница 1: ...ns for use Ambu aScope For Single Patient use only Sterile For use by trained clinicians physicians only For in hospital use Ambu aScope Monitor For use by trained clinicians physicians only For in ho...

Страница 2: ...800 ambude www ambu de UK Ambu Ltd 8 Burrel Road St Ives Cambridgeshire PE27 3LE Tel 44 1480 498 403 Fax 44 1480 498 405 www ambu com Italy Ambu S R L Via Paracelso 18 Centro Direzionale Colleoni 2004...

Страница 3: ...to an external monitor video recorder 15 10 Clinical Application 15 11 Preparation for Use 15 12 Use of the Ambu aScope system 16 12 1 Injection and control of the Luer channel 17 12 2 Removal proced...

Страница 4: ...loose parts or the bending section does not work as intended Do not touch the distal tip of the insertion cord or allow it to strike other objects The lens surface of the distal tip is fragile and vis...

Страница 5: ...conventional cleaning and sterilization procedures 2 Intended Use The Ambu aScope is intended for use as an aid in the placement of an Endotracheal Tube ETT directly or through an intubating laryngea...

Страница 6: ...e Ambu aScope Working length of the Ambu aScope insertion cord Maximum width of inserted portion Min ETT ID 6 mm Minimum ET tube inner diameter 6 0mm see section 12 Field of view Operating time of the...

Страница 7: ...and electrical waste WEEE Only applicable for the Monitor Li ion Battery type Lithium ion Only applicable for the battery inside the Ambu aScope Monitor Re chargeable battery Only applicable for the...

Страница 8: ...duct specifications Ambu aScope Optical System Field of View 80 Direction of View 0 forward viewing Depth of Field 2mm 50 mm 0 1 1 968 inch Illumination method LED LTW C282DS5 SE Insertion cord Distal...

Страница 9: ...al standard NTSC Video out connection 3 5mm jack socket Video out cable 3 5mm jack plug to RCA jack plug Storage Temperature 10 40 C 50 104 F Relative humidity 10 90 Mounting interface Mounting interf...

Страница 10: ...r battery icon on the screen changes from green fully charged battery via orange half battery capacity to red low bat tery capacity within 30 minutes it is recommended that the Ambu aScope Monitor is...

Страница 11: ...t Function Material 1 Monitor frame PC Polycarbonate ABS Acrylonitrile Butadiene 2 Monitor screen Shows the picture from the camera Glass 3 Bracket Secures the monitor to e g an IV pole POM GF25 Polyo...

Страница 12: ...sportation purposes Cardboard Table 5 Functions and materials 8 2 1 Monitor placement on the bracket The Ambu aScope Monitor can be placed on a flat surface But to secure the Ambu aScope Monitor it is...

Страница 13: ...alf time left orange Time is expiring Less than 5 minutes left red Plug is connected and the monitor battery is above half charged green Plug is connected and the monitor battery is half charged orang...

Страница 14: ...device should not be used A physician who is familiar with this device can perform the preparation for use in a time range of 1 4 minutes The tests should be conducted in a manner consistent with acce...

Страница 15: ...tructions do not explain or discuss clinical intubation procedures They describe only the basic operation and precautions related to the operation of this Ambu aScope system Before initial use of the...

Страница 16: ...rocedure turn the Ambu aScope off in between sessions and place it on a sterile surface Be aware of the total operating time limit of 30 minutes during a period of 8 hours from first switching on 12 3...

Страница 17: ...d collection schemes for disposal of batteries In order to remove the battery use a Torx screwdriver to remove the battery lid 13 Trouble shooting guide If problems occur with the system please use th...

Отзывы: