16
Working at the opposite ends of the tubes to
the burner, locate & position two couplers so that
the socket heads are facing outwards & the
pre-fitted bolts in the couplers line up with the
locating holes in the tubes.
Do not fully tighten at
this stage.
2x 2x
4
Slide U bend into the open end of the couplers
ensuring the pre-fitted bolts engage in the pre-cut
holes in the U tube section. Tighten all four
clamping bolts to provide a tight grip between
tubes & U tube section.
1x 1x
Remove protective film before starting.
The reflectors supplied all have the same hole
positions, however, each end reflector should
be positioned with the holes for the end caps
(position arrowed) outermost.
Starting at the burner end, slide the reflectors
through the brackets until they are all roughly in
position along the heater, referring to the assembly
diagram showing overlaps. Measure the distance
between the end of the burner end tubes & the
centre of the end bracket,
This should be
150mm
, slide bracket along tubes to adjust, then
tighten U bolts on the end bracket.
2.4.3 REFLECTORS
2x 3x
6
CAUTION — SHARP EDGES!
Slide end reflector so that the innermost
slotted holes line up with 1st bracket fixing holes,
then fix in place using M6 x 35mm pins, washers
& nuts.
2x 2x
5