other  and  insert  M8  self  tapping  screws         
provided. 
 
6. Repeat the procedure for 3rd set of outer 
canopies. 
 
 

2.2.9.3  Four Module Units 

 
1. Slide on the two halves to cover the centre 
section of the heaters and fit closing plates to 
each end (P). 
 
2. Slide on two more outer canopies. 
 
3. Stop short of the canopies already fitted and 
fit closing plates (P). 
 
4. Insert the ends of the second set of canopies 
inside the first set at the central joint. 
 
5. A slot  is located 15mm from the end of each 
canopy. Align each slot i.e. one on top of each 
other  and  insert  M8  self  tapping  screws         
provided. 
 
6. Repeat the procedure for 3rd and 4th set of 
outer canopies. 

2.2.9  Outer Canopy's 

The outer canopies are made up of identical half 
covers (L) which engage into the side of the  
inner reflectors and join at the centre by way of 
a closing plate which holds the two halves     
together. Install the outer canopies using the 
following method; 
 

2.2.8.1  Two Module Units 
 

1. Slide on the two halves to cover the 1st    
section of the heaters and fit closing plates to 
each end to the second set of canopies. 
 
2. Slide on two more outer canopies. 
 
3. Stop short of the canopies already fitted and 
fit closing plates (N). 
 
4. Insert the ends of the second set of canopies 
inside the first set at the central joint. 
 
5. A slot is located 15mm from the end of each 
canopy. Align each slot i.e. one on top of each 
other  and  insert  M8  self  tapping  screws         
provided. 
 
 

2.2.8.2  Three Module Units 

 
1. Slide on the two halves to cover the centre 
section of the heaters and fit closing plates to 
each end (P). 
 
2. Slide on two more outer canopies. 
 
3. Stop short of the canopies already fitted and 
fit closing plates (P). 
 
4. Insert the ends of the second set of canopies 
inside the first set at the central joint. 
 
5. A slot  is located 15mm from the end of each 
canopy. Align each slot i.e. one on top of each 

Remove the protective plastic coating.

 

Содержание Vision VSO Series

Страница 1: ...1974 or relevant codes of practice In addition the installation must be carried out in accordance with the current IEE wiring regulations BS 7671 BS 6896 Industrial Commercial and any other relevant...

Страница 2: ...th and Safety AmbiRad heaters must be installed in accordance with the relevant provisions of the Gas Safety Installations and Use Regulations 1998 Due account should also be taken of any obligations...

Страница 3: ...ollowing tools and equipment are advisable to complete the tasks laid out in this manual Suitable alternative tools may be used 2 2 Assembly Notes refer fig s 1 7 2 2 1 Tubes Identify and position tub...

Страница 4: ...he heater have been fully assembled and hung in position see Final Fixings section 2 2 7 2 3 All remaining U bolts on the RETURN TUBE should also be tightened to achieve a minimum torque setting of 15...

Страница 5: ...A A A A A TWO MODULE THREE MODULE FOUR MODULE 3400mm TUBE 3400mm TUBE 3400mm TURBULATOR 976mm TURBULATOR 2600mm TURBULATOR 976mm TURBULATOR 3040mm TURBULATOR 976mm TURBULATOR 2600mm TURBULATOR 3400mm...

Страница 6: ...7 1 Overshield Reflectors Overshields J1 are fitted to the underside of and run in parallel to the inner reflectors One end of the overshield has two holes for direct fixing to the reflector the other...

Страница 7: ...IELD 201928 1680 OVERSHIELD 201928 1680 OVERSHIELD 201931 1200 OVERSHIELD 201931 1200 OVERSHIELD BURNER END BURNER END BURNER END AV NUT WASHER CROSS MEMBER OVERSHIELD REFLECTOR WASHER SET PIN EXPANSI...

Страница 8: ...second reflector onto the same bolt using the FIRST slot in from the end and OVERLAP the first reflector This should create a 77mm overlap Secure using large washers and anti vibration nuts 5 The slot...

Страница 9: ...9 Locate the fourth reflector onto the same bolts using the FIRST slot in from the end and OVERLAP the third reflector This should create a 84mm overlap Secure using large washers and anti vibration...

Страница 10: ...21 Page 10 of 20 TWO MODULE THREE MODULE FOUR MODULE 114mm OVERLAP 67mm OVERLAP 77mm OVERLAP 84mm OVERLAP 77mm OVERLAP 50mm OVERLAP WASHER REFLECTOR WASHER REFLECTOR FIXING DETAIL D AV NUT Fig 3 Refle...

Страница 11: ...which holds the two halves together Install the outer canopies using the following method 2 2 8 1 Two Module Units 1 Slide on the two halves to cover the 1st section of the heaters and fit closing pla...

Страница 12: ...AN VIEW FROM ABOVE HEATER 30mm OVERLAP 30mm OVERLAP 30mm OVERLAP 90mm OVERLAP 30mm OVERLAP 30mm OVERLAP 55mm 35mm E SCRAP PLAN VIEW FROM ABOVE HEATER SCRAP PLAN VIEW FROM ABOVE HEATER FOURTH CANOPY TH...

Страница 13: ...ly On VSXO only slide the heat exchanger assembly E1 onto the LEFT HAND TUBE when viewed from behind ensuring it is fully engaged Secure with pinch screws 2 2 13 Fan Assembly On unitary heaters only s...

Страница 14: ...e end of the fitting and internally round the end of the tube Enter the fitting into the tube using a slight rotating movement to spread the jointing compound uniformly until a penetration of 75mm 3in...

Страница 15: ...J2 Expansion Plate J3 Cross Member K Insulation L Outer Canopy M Canopy End Cap N Closing Plates P End Mouldings optional Ref Description A Radiant Tubes B Suspension Brackets C Return Bend D Coupler...

Страница 16: ...nitary heaters E3 Damper Herringbone F1 Forced Burner VSXO F2 Induced Burner VSO G Turbulators Fig 6 Three Module drawings A B C G P J1 J2 D H J3 K L M N F1 F2 E1 E2 E3 H Reflectors J1 Overshields J2...

Страница 17: ...unitary heaters E3 Damper Herringbone F1 Forced Burner VSXO F2 Induced Burner VSO G Turbulators H Reflectors J1 Overshields J2 Expansion Plate J3 Cross Member K Insulation L Outer Canopy M Canopy End...

Страница 18: ...Doc No 700021 Page 18 of 20 Notes...

Страница 19: ...Doc No 700021 Page 19 of 20 Notes...

Страница 20: ...cleaning of the reflectors with a soft cloth and a mild detergent non solvent based cleaners only in water can be undertaken Additional removal of dust from the radiant tubes burner and heat exchange...

Отзывы: