Doc No 700111 (06-15), Page 24
2.2.8.1 Model 200 S50 fan orifice plate
This model has a different fan orifice plate (Part
No.202254) to all other models in the range. It
is supplied with every burner as a loose item
and should be discarded if not needed. This
must be fitted to the 200 S50 model only.
Note: There should be 22 10mm x 10mm
square holes in the replacement plate.
Remove the top cover of the burner to expose
the combustion fan.
Remove the four screws (arrowed), three of
which can not be seen in the photograph. Lift
out the fan assembly to access the fan.
Remove the four fixing screws securing the
existing orifice plate, then fit the replacement
orifice plate with the correct air inlet hole
orientation as shown below.
2.2.9 Heater Configurations
The sketches shown on the following page
show various heater configurations for the
model series dependent on heater length and
rating. It is important not to configure a heater
outside of these recommendations.
2.2.10 Detailed Assembly Drawings
The following pages show the technical
dimensional details of the range of heaters.
Please note the heater type, length and
reference number from the delivery/advice note
before identifying the correct model drawing.