background image

 
 
 

 

 

15

  

    

      

 

 
                                      
 

 

 

 
 
 

      

      

   

 

 
                      
 
 
 
 
 
 

Select the device you 
have from the device 
list, then press 

Next

 

 

If Bluetooth is off, the popup 
message will appear: The 
Bluetooth of the current 
mobile phone is turned off, 
whether to open the Bluetooth 
search device. 

Tap 

Open 

  

Allow WS View to 
enable Bluetooth. 
Tap 

Allow

, then tap 

Next 

 

Press “Configure 
a New Device” 

The  app  will  search  the  device. 
Please ensure your phone and device 
are close to each other within 5m 

Operate as per the 
information, tick the  
box to confirm 
“completed operation”,  
press 

Next.

 

 

Содержание WS-1950

Страница 1: ...3 Console Factory Reset Steps 10 6 Key function 10 7 Connect the display console to your Wi Fi network via Bluetooth 11 7 1 Download the awnet smart phone or tablet app 11 7 2 Configure Wi Fi via Blu...

Страница 2: ...utdoor Thermo Hygrometer 8 Channel optional 34 13 Specifications 36 13 1Wireless Specifications 36 13 2 Measurement Specifications 37 13 3 Power Consumption 37 14 Maintenance 37 15 Troubleshooting Gui...

Страница 3: ...of the tallest obstruction For example if the building is 20 tall and the mounting pole is 6 tall install the sensor array 4 x 20 6 56 away 4 Mount the sensor array in direct sunlight for accurate tem...

Страница 4: ...ith U Bolts 1 User manual 1 Zip bag for 1pc 10mm single head wrench 1 USB cable 5 2 Recommended Tools Precision screwdriver for small Phillips s screw on wind vane and wind cups Adjustable wrench for...

Страница 5: ...or is not positioned correctly during installation 5 3 2 Install wind cups Push the wind speed into the shaft as shown in Figure 3 Tighten the set screw with as shown in figure 4 Make sure the wind sp...

Страница 6: ...unting Final assembly is shown in Figure 6 Figure 6 The plate and U Bolts are not yet needed at this stage but doing this now may help avoid damaging wind vane and wind speed cups later 5 3 4 Install...

Страница 7: ...lly flash once every 16 seconds the sensor transmission update period Figure 8 Figure 9 Note If no LED light up or is permanently on make sure the batteries are inserted the correct way or a proper re...

Страница 8: ...950 AC 2 Unfold the desk stand and place 5 to 10 feet away from the outdoor sensor array per Figure 11 3 Sensor arm containing temperature and humidity sensor 4 Remove the battery door on the back of...

Страница 9: ...5 4 1 Screen Display Figure 13 1 Wind direction 9 Rainfall 2 Wind speed 10 Rate of Change of Pressure Graph 3 RF icon 11 Weather forecast 4 8 Channel Indoor Outdoor Thermo Hygrometer recycle icon opti...

Страница 10: ...e LCD for 3 seconds after power reset the display will attempt to register the outdoor sensor array for 3 minutes Figure 14 5 4 3 Console Factory Reset Steps Under AC power using optional AC adapter p...

Страница 11: ...Rain Weekly Rain and Monthly Rain While in Pressure mode press to switch between Relative pressure and Absolute pressure LIGHT Press to adjust the LCD backlight brightness high medium and off Press t...

Страница 12: ...er Run the awnet app from your mobile device s home screen When prompted Allow awnet to access your location choose Allow While Using App If you do not select this option your phone will not connect t...

Страница 13: ...each other within 5m If you have more than one device they will all be listed Select the device The last four digits of device ID is same as its last four digits of MAC address If cannot find your de...

Страница 14: ...erval in minutes Make a note of the MAC address You will need this to create an account on AmbientWeather net Upload your data to Wunderground com Register an account and station at Wuderground com En...

Страница 15: ...le phone is turned off whether to open the Bluetooth search device Tap Open Allow WS View to enable Bluetooth Tap Allow then tap Next Press Configure a New Device The app will search the device Please...

Страница 16: ...he last four digits of device ID is same as its last four digits of MAC address If cannot find your device ID press refresh to update 8 The app will connect to the console automatically 10 Press Scan...

Страница 17: ...ill be displayed To change any of the console settings click on the device field Figure 17a Upload your data to AmbientWeather net Tap ON and select an upload interval in minutes Make a note of the MA...

Страница 18: ...t the same time 8 1 AmbientWeather net Note This is best done on a computer desktop or laptop Visit www AmbientWeather net to create an account and select Add Device as shown in Figure 18 Figure 18 Ne...

Страница 19: ...com store apps details id net ambientweather dashboard Ambient Weather Dashboard for iOS https apps apple com us app ambient weather dashboard id1426025887 8 1 2 IFTTT The AmbientWeather net service c...

Страница 20: ...t real time and past weather information generated by the devices they have set up at AmbientWeather net Link your account to get started say hey google Ambient Weather weather report This will provid...

Страница 21: ...down MODE Year Press TEMP or WIND to adjust year up or down MODE Month Press TEMP or WIND to adjust month up or down MODE Day Press TEMP or WIND to adjust day up or down MODE Pressure Units of Measure...

Страница 22: ...9 1 2 Rate of Change of Pressure Graph The rate of change of pressure graphic is shown to the left of the barometric pressure and signifies the difference between the daily average pressure and the 30...

Страница 23: ...in a 24 hour period Daily Rain is defined as the rainfall since midnight 00 00 Weekly Rain is defined as the calendar week total and resets on Sunday morning at midnight Sunday thru Saturday Monthly...

Страница 24: ...LIGHT button again a b Figure 23 9 5 2 Setting High and Low Alarms While the High Alarm is displayed reference Section 9 8 1 press and hold the MODE button for 2 seconds to enter the High Alarm Set M...

Страница 25: ...disappear MODE Alarm High Outdoor Temperature Press TEMP or WIND to adjust alarm value up or down Press RAIN PRE to turn the alarm on The alarm icon will appear Press RAIN PRE to turn the alarm off T...

Страница 26: ...rn the alarm off The alarm icon will disappear MODE Exit alarm settings mode MODE 2 seconds means press and hold the ALARM button for two seconds MODE means press the MODE button Figure 1 9 6 Backligh...

Страница 27: ...c pressure Please allow at least one month for the weather station to learn the barometric pressure over time Sunny Partly Cloudy Cloudy Rainy Snowy Pressure increases for a sustained period Pressure...

Страница 28: ...displayed To view the low alarm settings press the MODE button again and the min values will be displayed as shown in Figure b To clear the min values press and hold the MODE button while the min val...

Страница 29: ...displayed as outlined in Section 0 press and hold the PRESSURE button for two seconds to view the absolute pressure and press and hold the PRESSURE button for two seconds again to return to relative...

Страница 30: ...nstructions in section Error Reference source not found and onwards first while you keep the assembled outdoor sensor package nearby although preferably not closer than 5 ft from the console This will...

Страница 31: ...ve a compass application Once rotated in the correct orientation lightly tighten the bolts a little more use a wrench to prevent further rotation Note Use the bubble level next to the rain sensor to m...

Страница 32: ...following optional sensors and the console receives and sends this data directly to Ambient Weather net or Wunderground com The data is not displayed on the console pass through only and sensor manage...

Страница 33: ...ur console please see Section 4 1 of the AQIN manual to sync your new AQIN sensor https ambientweather com mwdownloads download link id 1097 12 1 Connecting optional sensors to console via the awnet a...

Страница 34: ...s WH31 the data display on the console and sends the data to Ambientweather net Note WH31P sensor body is not waterproof the probe is please when installing sensor body under a protected are such as a...

Страница 35: ...ts up to eight transmitters To set each channel number the default is Channel 1 change Dip Switches 1 2 and 3 as referenced in Figure 4 Temperature Units of Measure To change the transmitter display u...

Страница 36: ...need to relocate the transmitters or receivers to avoid intermittent communication 1 Line of Sight Rating This device is rated at 300 feet line of sight no interference barriers or walls but typicall...

Страница 37: ...using Wi Fi upload to AW net is 5 6 months the limiting factor will be the amount of use of the backlight Expected battery life using the optional AC adapter is 12 18 months Sensor Array 2 x AA batte...

Страница 38: ...ement walls or air conditioning units Use the calibration feature to offset installation issues related to radiant heat sources Reference Section 9 Relative pressure does not agree with official repor...

Страница 39: ...s strongly damages the environment Reading the User manual is highly recommended The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occ...

Страница 40: ...use 6 applications and uses that this product was not intended 7 the products inability to receive a signal due to any source of interference or metal obstructions and 8 extreme acts of nature such as...

Страница 41: ...reproductive harm in humans or test animals Proposition 65 does not clarify whether exposure is to be measured only in normal operation or in the event of misuse such as intentionally damaging incine...

Отзывы: