Ambient Weather WS-1001-WiFi OBSERVER Скачать руководство пользователя страница 17

 

Version 1.0  

 

©Copyright 2014, Ambient LLC. All Rights Reserved. 

 

 

 

Page 17 

No 

Description 

No 

Description 

Graph (barometer, temperature or humidity) 

11 

Heat Index 

Wind Direction 

12 

Rainfall 

Wind Speed 

13 

Date and Time 

Wind Gust 

14 

Sunset 

Wind Chill 

15 

Moon Phase 

Internet Connectivity 

16 

Sunrise 

WiFi Connectivity 

17 

Barometer 

Indoor Temperature & Humidity 

18 

UV 

Outdoor Temperature & Humidity 

19 

Solar Radiation 

10 

Dew Point 

20 

Low  Battery  Indicators  (only  displayed 
when batteries are low) 
IN  –  Indoor  Thermo-hygrometer-barometer 
transmitter 
OUT – Outdoor Sensor Array 

 

Icon 

Description 

 

Brightness control key 

Press this key to enhance the brightness 

 

 

Brightness control key 

Press this key to decrease the brightness

 

 

Backlight on/off key 

Press this key to turn on/off the display 

 

Graph display key 

Press this key to choose between barometric pressure, indoor and 
outdoor temperature and indoor and outdoor humidity

 

 

Pressure display key 

Press this key to choose the display between Absolute pressure 
and Relative pressure.

 

 

Rain key 

Press this key to Shift the display between Rain Rate, Rain Day, 
Rain Week, Rain Month, and Rain Year. 

 

History key 

Press this key to enter History Mode 

 

Set key 

Press this key to enter Set Mode 

6.2

 

History Mode 

 

View and reset minimum and maximums. 

 

Содержание WS-1001-WiFi OBSERVER

Страница 1: ...nsmitter 14 5 5 Best Practices for Wireless Communication 15 5 6 Display Console 15 6 Display Console Operation 16 6 1 Home Screen Display 16 6 2 History Mode 17 6 2 1 Archive Memory Mode 18 6 2 2 Rec...

Страница 2: ...ation and troubleshooting To download the latest manual and additional troubleshooting tips please visit http ambientweather wikispaces com ws1001 wifi 2 Warnings and Cautions Warning Any metal object...

Страница 3: ...and change the rechargeable batteries every 2 3 years Provide easy access to the weather station 2 Avoid radiant heat transfer from buildings and structures In general install the sensor array at leas...

Страница 4: ...mo hygrometer barometer 5 1 Parts List QTY Item Image 1 Display Console Frame Dimensions LxWxH 7 75 x 5 75 x 0 75 LCD Dimensions LxW 6 25 x 3 5 1 Thermo hygrometer barometer transmitter 1 Thermo hygro...

Страница 5: ...Pole straight and crimped 2 Pole mounting U bolt 4 Pole mounting clamps 4 Pole mounting U bolt nuts 1 Allen wrench 1 User manual 5 2 Recommend Tools Precision screwdriver for small Phillips screw on b...

Страница 6: ...direction 7 Thermo hygrometer Sensor measures temperature and humidity 2 Wind Speed Sensor measures wind speed 8 UV Sensor 3 Solar collector 9 Solar Radiation Sensor 4 Rechargeable battery compartment...

Страница 7: ...2 a Locate and align the flat key on the wind vane shaft to the flat key on the wind vane and push the vane on to the shaft b tighten the set screw with the hex wrench included a b Figure 2 5 3 2 Inst...

Страница 8: ...Version 1 0 Copyright 2014 Ambient LLC All Rights Reserved Page 8 Reference Figure 4 Locate and align the groove on the sensor array and mounting pole Figure 4...

Страница 9: ...s Reference Figure 6 Locate the battery door on the bottom of the sensor array Turn the set screw counter clockwise to open the battery compartment Insert the 3xAA rechargeable batteries included The...

Страница 10: ...Version 1 0 Copyright 2014 Ambient LLC All Rights Reserved Page 10 Figure 6...

Страница 11: ...ts as shown in Figure 7 Tighten the mounting pole to your mounting pole with the U Bolt assembly Make sure your mounting pole is as far away from the temperature sensor as possible as shown in Figure...

Страница 12: ...Rights Reserved Page 12 Figure 8 1 Reference Figure 9 Locate the four wind vane compass rose indicators of N E S W representing North East South and West Align the compass rose direction upon final i...

Страница 13: ...tton and Transmitter LED In the event the sensor array is not transmitting reset the sensor array With an open ended paperclip press and hold the RESET BUTTON for three seconds to completely discharge...

Страница 14: ...usiness or facility will correspond closely to the actual barometric pressure outside Note The thermo hygrometer transmitter transmits directly to the display console For best results place between 5...

Страница 15: ...line of sight no interference barriers or walls but typically you will get 100 feet maximum under most real world installations which include passing through barriers or walls 4 Metal Barriers Radio f...

Страница 16: ...s manual includes quick menu boxes as shown below signifying how to access a setting from home screen For example to access Recall and delete annual archive memory from the home screen press the Histo...

Страница 17: ...nsmitter OUT Outdoor Sensor Array Icon Description Brightness control key Press this key to enhance the brightness Brightness control key Press this key to decrease the brightness Backlight on off key...

Страница 18: ...Uncheck parameter to clear Clear selected parameter 1 scroll up scroll down View archive memory return home 1 The popup message Are you sure you want to clear the max min Select to highlight Yes and t...

Страница 19: ...nt LLC All Rights Reserved Page 19 Figure 17 Recall annual records Recall page scroll left scroll right scroll up scroll down View graphs return home 6 2 2 Recall Delete Annual Archive Memory Recall a...

Страница 20: ...l Rights Reserved Page 20 Figure 18 Delete annual record scroll left scroll right Recall annual record return to archive memory mode 6 2 3 Page Selection While viewing the annual archive memory press...

Страница 21: ...s Reserved Page 21 Figure 19 Increase page number Decrease page number Scroll digit to left scroll digit right Toggle OK or cancel then press to confirm Toggle OK or cancel then press to confirm 6 2 4...

Страница 22: ...ght 2014 Ambient LLC All Rights Reserved Page 22 Figure 20 Zoom in Y axis Zoom out Y axis scroll x axis time left scroll x axis time right Recall annual archivc data scroll parameter pages Return to M...

Страница 23: ...me 6 3 1 Set Date and Time Set the date and time Set automatic time synchronization 1 Set Time hour minute second Press to set the time The hour field will turn red Press Press or to select hour minut...

Страница 24: ...ly update the time when DST changes 4 Set Time Server The default time server is time nist gov Press to set the time server Press again to turn ON Press to toggle ON or OFF Press to immediately to hig...

Страница 25: ...hange the temperature units of measure between inHg mmHg and hpa 6 3 5 Wind Speed Units of Measure x 5 Press to change the wind speed units of measure between mph bft beufort scale ft s m s km h and k...

Страница 26: ...cklight or adjust the brightness based on the time of day Figure 23 adjust up or check adjust down or uncheck scroll left scroll right scroll up scroll down return home 6 3 11 Longitude and Latitude x...

Страница 27: ...increase or decrease the value Press or to change the remaining longitude variables Figure 24 To determine your longitude and latitude we recommend the following website www bing com maps Reference Fi...

Страница 28: ...ure and ABS absolute pressure Note The weather station console displays two different pressures absolute measured and relative corrected to sea level To compare pressure conditions from one location t...

Страница 29: ...6 3 16 Rainfall Season x 13 Press to change the beginning of the rainfall yearly season month The default is January 6 3 17 Archive Interval x 14 Changes the archive interval for historical data and g...

Страница 30: ...acter and press to select the character Press to return to the Wunderground com setup page 2 Set Password Press to highlight the Password Enter your password obtained from Wunderground com Press to di...

Страница 31: ...D obtained and password you entered in the console s Weather Server page Note If Wunderground com is not updating make sure the Station ID and Password are correct The Station ID is all capital letter...

Страница 32: ...displayed on the home page If wireless connectivity is successful and you are reporting to Wunderground com the WiFi icon will be displayed under the wind chill display on the home page Figure 27 Sele...

Страница 33: ...ggle the alarm ON or OFF When a weather alarm condition has been triggered the alarm will sound for 120 seconds and the corresponding icon will flash until the weather condition is no longer present P...

Страница 34: ...alibrated value Select value Select value Scroll field up Scroll field down Enter sub setup mode return to home To adjust the parameter press to scroll to the parameter you wish to change Press to hig...

Страница 35: ...s not operating for the entire year 1 Temperature errors can occur when a sensor is placed too close to a heat source such as a building structure the ground or trees To calibrate temperature we recom...

Страница 36: ...y and did not point the direction reference to true north 5 The default conversion factor based on the wavelength for bright sunlight is 126 7 lux w m2 This variable can be adjusted by photovoltaic ex...

Страница 37: ...rces for sensor calibration to reduce manufacturing and degradation errors Do not compare your readings obtained from sources such as the internet radio television or newspapers The purpose of your we...

Страница 38: ...register indoor transmitter Press or key to popup the Message Box Are you sure you want to clear the max min Press or to select Yes or No Press the key or key to confirm the selection 5 Reset to Fact...

Страница 39: ...2014 Ambient LLC All Rights Reserved Page 39 Figure 31 Select Setting Select Setting Select year history file Select year history file Scroll field up Scroll field down Start or stop backup return to...

Страница 40: ...Indoor Humidity 5 Outdoor Temperature F 6 Outdoor Humidity 7 Dew Point F 8 Wind Chill F 9 Wind mph 10 Gust mph 11 Wind Direction 12 ABS Barometer inHg 13 REL Barometer inHg 14 Rain Rate in h 15 Daily...

Страница 41: ...d and another measurement made in as similar a way as possible with a second device instrument Dew Point The dew point is the temperature at which a given parcel of humid air must be cooled at constan...

Страница 42: ...m units of measurement Same as millibars 1 hPa 1 mbar Hygrometer A hygrometer is a device that measures relative humidity Relative humidity is a term used to describe the amount or percentage of water...

Страница 43: ...Wind direction is the direction from which the wind is blowing 8 Specifications 8 1 Wireless Specifications Line of sight wireless transmission in open air 330 feet 100 feet under most conditions Upda...

Страница 44: ...b back and forth removing dirt from the tipping mechanism and rain collector hole Step 5 Remove the cotton swab and flush with water to remove any remaining dirt Step 6 Re enter the rain totals record...

Страница 45: ...Version 1 0 Copyright 2014 Ambient LLC All Rights Reserved Page 45 Figure 35 Figure 36...

Страница 46: ...nicate to the display console The sensor array may have initiated properly and the data is registered by the console as invalid and the console must be reset The reset button is next to the LED near t...

Страница 47: ...el mounting solution Data not reporting to Wunderground com 1 Confirm your password is correct It is the password you registered on Wunderground com Your Wunderground com password cannot begin with a...

Страница 48: ...in unauthorized grounds strongly damages the environment Reading the User manual is highly recommended The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any...

Страница 49: ...limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and only...