13
Copyright 2018 by Amber Kinetics. All rights reserved.
2 - SAFETY
1,200lbs (~550kg). The Capsule Lid weighs
approximately 400lbs (~200kg). Always use an
appropriately rated crane/hoist along with
appropriately rated equipment (such as straps,
chains, shackles, and/or hooks) when hoisting any
of these components.
•
Remain well clear of any component during any
hoisting operation to prevent serious injury or
death in the event of any hoist failure. Never use
any body part to position or align the components,
such as when lowering the M32 flywheel and
Capsule into the hole, Instead, use one or more
tagline(s) while remaining well clear of the
components.
•
The installation hole and protruding Capsule pose
various tripping and/or falling hazards. Remain
clear of all installation holes and be aware of your
surroundings at all times.
•
The M32 flywheel produces hazardous voltages
and currents when the Flywheel Rotor is spinning
at any speed, even when the utility grid and/or
other power sources are lost or disconnected.
•
All wiring and connections may have hazardous
voltages and currents at any time. Only qualified
and authorized personnel may install and/or
maintain the M32 flywheel and associated
components.
•
Be sure to use safety lockout devices on all
affected circuit breaker(s) and/or power shut-
off(s) when working on the M32 flywheel or
associated components to prevent accidental
power-on and death from electrical shock,
•
The M32 flywheel contains no user-serviceable
parts. Under no circumstances should you open the
Flywheel Housing or perform any other servicing or
repair aside from that explicitly described in this
manual. Always contact Amber Kinetics for any
maintenance or repair that is not described in this
manual.
•
Only use the M32 flywheel in accordance with the
information provided in this manual, any other M32
documentation, and all locally applicable standards
and directives. Any other use or application may
cause death, personal injury, and/or property
damage.
•
Altering the M32 flywheel, such as (but not limited
to) modifications or conversions, is only permitted
with the express written permission of Amber
Kinetics, Inc. Unauthorized alterations will void all
guarantee and warranty claims and will usually void
the operation permit. In no event shall Amber
Kinetics be held liable for any damage caused by
such changes.
•
The M32 flywheel can continue to spin for up to 15
days following removal of DC power. Contact
Amber Kinetics for assistance before approaching
any M32 flywheel while it is still spinning.
•
The Capsule lid must be in place at all times while
the Flywheel Rotor is spinning.