TPD
Jul 2016
18
Amate Audio
Finally, select to enable or disable the filter: Enabled On/Off.
•
High Pass
– First adjust the High Pass Filter cut-off frequency. To switch it off, turn
the rotary knob counter-clockwise until frequency reaches 20 Hz.
Second, press the rotary knob and select from the available types and slopes:
Type: Butterworth, Slopes: 6dB, 12dB, 18dB or 24dB
Type: Bessel. Slopes: 6dB, 12dB, 18dB or 24dB
Type: Linkwitz-Riley. Slope: 12dB or 24dB
Finally, select to enable or disable the filter: Enabled On/Off
6.2.4 Parametric EQ
Select between one of the 10 available Equalizers on each input channel by using
the keys
< Select
and
Select >
. Browse the parameters by turning the rotary knob
and push the knob to select and confirm the values. The following parameters can
be adjusted for each EQ:
•
Enabled
– When set On, the currently selected EQ is on line.
•
Freq
- EQ center frequency.
•
Gain
- EQ level gain.
•
Q
- EQ Bandwidth. For shelving filters the Q sets the transition in dB/Oct.
•
Type
- Shape of EQ. The available types are:
Bell: Modifies the gain of a certain frequency range, with bell shape
Notch: Eliminates a range around a center frequency
High-Shelf: Modifies the gain of all the range above a selected frequency.
Low-Shelf: Modifies the gain of all the range below a selected frequency.
All Pass: Modifies the phase response, without influencing the frequency response.
Band Pass: Filters out all the range except the defined band.
High Pass: Filters out all the range below a certain frequency.
Low Pass: Filters out all the range above a certain frequency.
Q: 2.36
In LR PEQ 1
Freq: 15000Hz
In LR LowPass
XOver
Type: BUT 24dB
In LR LowPass
XOver
Type: BUT 24dB
In LR HighPass
XOver
Freq: 40Hz
In LR HighPass
XOver
Type: Bell
In LR PEQ 1
Freq: 1000Hz
In LR PEQ 1
Gain: 0.00dB
In LR PEQ 1
Enabled: On
In LR PEQ 1
Содержание TPD
Страница 58: ......