NITID S12W
Dec 2022
7
Amate Audio
Fig. 6.
Back energy rejection at 40 Hz / 50 Hz / 63 Hz
2.
CONTROL AND CONNECTION PANEL
The S12W control panel contains the following elements:
A) TOUCHSCREEN:
Displays information about the System status: current preset,
amplifier status and signal input level. Allows the user to configure the system:
Preset selection, Delay, Gain, Limiter, polarity, ECO mode on/off, Front LEDs
on/off, etc. For more information about the available functionality, read the Annex I
of this manual.
NOTE:
For preventing the access to Main Menu with a PIN pattern, please refer to
Annex I.
B) MODEL DATA:
The basic data of the model is found here:
- Model reference
- Amplifier program power (Watts)
- Maximum Sound Pressure Level Continuous delivered by the system (dB SPL)
C) BALANCED INPUT/LINK:
XLR-3 Female balanced signal connector for signal input.
XLR-3 Male connector for parallel connection of various cabinets with the same input
signal.
Nominal Input sensitivity: +2dBu (1 Vrms)
Maximum Input Voltage without clipping: +14dBu (4Vrms)
Maximum Input Voltage: +20dBu (8Vrms)
IMPORTANT:
Please always use balanced microphone cable with the
following pin assignment: 1= Shield (Ground) 2= Live (+) 3= Return (-)
D)
AC MAINS INPUT/LINK:
Mains supply connection via PowerCon.
Blue connector for AC in.
Grey connector to feed other units in parallel. Linking up to ten units is
possible, if a quality cable of a minimum section of 3x2.5mm
2
is used.
Connecting more than ten units in parallel may lead to a voltage drop in the
cable that will reduce the equipment performance.
Always use mains power cable supplied by manufacturer. Never connect
NITID cabinets to an unearthed mains supply or by using an unearthed
mains cable
Содержание Nitid S12W
Страница 1: ...User s manual December 2022...