1. Set the AFR-200 terminal face up on a flat surface to avoid scratches on
display.
2. Using the mounting guide as a template, mark the location of the upper and
lower mounting holes on the wall. It is recommended to mount the terminal
49.2” from the floor to the baseline on the template. *Adjust for staff height as
necessary.
Note: Pay attention to the orientation. The back plate should only be
mounted one-way as it is keyed to fit into the back of the face scan reader.
3. Install anchors at the marks and attach the mounting bracket to the wall.
4. Feed power and communication wires through the knockout in the bottom of
the mounting bracket.
5. Install the four screws attaching the metal back plate to the mounting bracket.
Make sure the two metal tabs are on top.
6. Plug in power connector.
7. Slide the terminal onto the two tabs located at the top of the back plate.
8. Secure the reader to the back plate by inserting and tightening the screw
located at the bottom of the unit.
Your terminal is now mounted to the wall and ready to connect the power
supply to the outlet.