38
7-Segment Display
Setting No.
Contents
Setting
Installer/Serviceman Notes
1
Maximum Defrost Interval
0:30 min
1: 60min.
2: 90min.
3: 120min.
2
Set Maximum Current
N/A
Future Use
3
Vertical Rise
0: Same Level
1: Outdoor Lower
2: Indoor Lower
4
System Verification Test (System Test)
0: ON 1: OFF
8
Pump Down
0: ON 1: OFF
9
Charge Mode
0: ON 1: OFF
10
Maximum Compressor RPS for Cooling
*
12
BOOST MODE Selection
0: ON 1: OFF
13
BOOST MODE Temperature
0: 105F, 1: 100F,
2: 95F, 3: 90F, 4: 85F,
5: 80F, 6: 75F, 7: 70F,
8: Always ON
* Depends on tonnage. Can adjust compressor RPS in each 0.5 RPS.
NOTES:
• Parameters as per factory setting are highlighted in bold and underlined.
• BOOST MODE is applicable only for AVXC200**1AB or later revision.
Screen 4 (Setting Mode 2)