Component Specifications
RT1300027 Rev. 0
4
December 1997
Part Number
Component Name
Test Procedures
C3680312
Switch, auger motor interlock/freezer light Type
Volt
Current
SPDT
125/250 VAC
5.0/5.0 amps
10533001
10533002
Switch, limit, cavity light, and dispensing
arms
Type
Volt
Current
SPST, NO
125/250 VAC
10 amps
10533003
Switch, limit, cavity light, and dispensing
arms
Used on:
SCD25TB
SQD25VW
Type
Volt
Current
SPST, NO
125/250 VAC
10 amps
12017823
Thermostat
Volt
Watt
Current
Resistance across terminals
Above 48° ±5°F
Below 15° ±7°F
Between 48° ±5°F and
15° ±7°F
120/240 VAC
1000 watts
10/5 amps
Open
Closed
Will stay in current state (either open or
closed) until either 48° ±5°F or 15° ±7°F is
reached.
10530702
Timer, defrost
Defrost period (minutes)
Defrost cycle (hours)
33
3.6
8
3
1
4
2
DEFROST
COMPRESSOR
CIRCUITRY
COMMON
LINE
12185504
Valve, water
Volt
Watt
Water pressure (inlet)
Max
Min
Fill rate
120 VAC, 60 Hz
20 watts
120 PSI
20 PSI
140 ± 10 CC's at 7.5 seconds