background image

Component Specifications

RT1300027   Rev. 0

2

December 1997

Part Number

Component Name

Test Procedures

  A0282803

   

Bulb

Volt
Watt

115/125 VAC
40 watts

M0360001

Bulb

Volt
Watt

115/125 VAC
6 watts

C8931604

   

Capacitor, compressor run

Volt
Capacitance

220 VAC
15 Mfd +10%
               -5%

C8931605

   

Capacitor, auger motor

Used on:
SCD25TBW
SQD25VW

Volt
Capacitance

220 VAC
17 Mfd +10%
               -5%

12049702

Compressor

Type
BTUH
Volt
Watt
Current
  Lock rotor
  Full load
Resistance
  Run windings
  Start windings

Fan cooled, R134a refrigerant
970 BTUH
115 VAC, 60 Hz
176  watts

21.3 amps
  1.6 amps

2.60 ohms
4.35 ohms

D7547411

  

Control, damper

Used on:
SQD25VW

Settings
#1
#4
#7

Closing temperatures
49

ƒ

F

42

ƒ

F

33

ƒ

F

D7547412

  

Control, damper

Used on:
SCD25TBW
SMD25TW

Settings
#1
#4
#7

Closing temperatures
47

ƒ

F

40

ƒ

F

30

ƒ

F

R0161092

  

Control, freezer temperature

Settings
#1–in
#1–out
#4–in
#4–out
#7–in
#7–out

Temperatures
    10

ƒ

F

   -11

ƒ

F

    13

ƒ

F

     -6

ƒ

F

    21

ƒ

F

     -5

ƒ

F

B2150504

      

Drier

Drier must be changed every time the system is opened for testing or
compressor replacement.

Desiccant                                           (20) 8 x 12 4AXH - 7 M>S> -Grams

10882105

Heater, cavity

Volt
Watt
Resistance

115 VAC
.667 

“

7.5% watts

6.61 

“

7.5% ohms

12049801

Heater, evaporator

Volt

115 VAC

Отзывы: