Component Specifications
RT1300027 Rev. 0
2
December 1997
Part Number
Component Name
Test Procedures
A0282803
Bulb
Volt
Watt
115/125 VAC
40 watts
M0360001
Bulb
Volt
Watt
115/125 VAC
6 watts
C8931604
Capacitor, compressor run
Volt
Capacitance
220 VAC
15 Mfd +10%
-5%
C8931605
Capacitor, auger motor
Used on:
SCD25TBW
SQD25VW
Volt
Capacitance
220 VAC
17 Mfd +10%
-5%
12049702
Compressor
Type
BTUH
Volt
Watt
Current
Lock rotor
Full load
Resistance
Run windings
Start windings
Fan cooled, R134a refrigerant
970 BTUH
115 VAC, 60 Hz
176 watts
21.3 amps
1.6 amps
2.60 ohms
4.35 ohms
D7547411
Control, damper
Used on:
SQD25VW
Settings
#1
#4
#7
Closing temperatures
49
F
42
F
33
F
D7547412
Control, damper
Used on:
SCD25TBW
SMD25TW
Settings
#1
#4
#7
Closing temperatures
47
F
40
F
30
F
R0161092
Control, freezer temperature
Settings
#1–in
#1–out
#4–in
#4–out
#7–in
#7–out
Temperatures
10
F
-11
F
13
F
-6
F
21
F
-5
F
B2150504
Drier
Drier must be changed every time the system is opened for testing or
compressor replacement.
Desiccant (20) 8 x 12 4AXH - 7 M>S> -Grams
10882105
Heater, cavity
Volt
Watt
Resistance
115 VAC
.667
7.5% watts
6.61
7.5% ohms
12049801
Heater, evaporator
Volt
115 VAC