RS5320014 Rev. 0
28
Troubleshooting
WARNING
!
To avoid risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge capacitors
before servicing, unless testing requires it.
Initial Power Up
Connect Power Cord (Door Closed)
5 to 10 Seconds
5 to 10 Seconds
Yes
Proceed to "Stand-By" Condition
No power applied to oven power cord.
Blown oven fuse (check interlock switch
module operation, monitor test).
Inoperative cavity thermal cut out.
Inoperative low voltage circuit board.
Inoperative high voltage circuit board.
Broken or improper wire connections.
1.
2.
3.
4.
5.
6.
No
MENU1
Error Code Appears?
No
Refer to Display Diagnostics page 22.
Yes
Inoperative interlock switch module,
contacts 4 & 5.
Inoperative high voltage circuit board.
Inoperative extended memory board.
Broken or improper wire connections.
1.
2.
3.
4.
No